Temp. & Humid. Chambers (Floor Standing) Temp. & Humid. Chambers (Table Top) Pharmaceutical Stability Test Chambers Clean Temp. & Humid. Chamber Plant Growth Chambers
|
General Applications
Temperature & Humidity Chambers Test for reliability, durability, climatic, freezing resistance,quality assurance, thermal endurance.
Specific Purpose Chambers Pharmaceutical Stability Test Chambers
Clean Environmental Test Chamber Designed for the process requiring environmental test in the clean condition. (ISO class 5 air cleanliness as per ISO 14644-1)
Plant Growth Chambers Optimal photosynthesis condition for plant growth. |
Product Name |
Temperature & Humidity Chambers |
|||
Model | TH-G | TH-I | TH-KH | |
Chamber volume (L) |
189, 302, 408, 800, 1000, 1540 |
189, 302, 408 | 189, 302, 408 | |
Temp. control | Operating temp. range (°C / °F) | -40 to 150 / -40 to 302 | -40 to 150 / -40 to 302 | -70 to 150 / -94 to 302 |
Fluctuation (± °C / °F) |
0.3 / 0.54 |
0.3 / 0.54 |
0.3 / 0.54 |
|
Variation (± °C / °F) |
0.5 / 0.9 |
0.5 / 0.9 |
0.5 / 09 |
|
Humid. control |
Operating humid. full range (% RH) |
25 to 95 |
20 to 95 |
25 to 95 |
Fluctuation (±% RH) |
0.4, 1.0, 2.0 |
0.4 |
0.4 |
|
Variation (±% RH) |
3.0 |
3.0 |
3.0 |
|
Control | Timer | Wait on/off | Wait on/off | Wait on/off |
Auto-tuning | • | • | • | |
Program function | • | • | • | |
Computer interface | RS-232 port | RS-232 port | RS-232 port | |
RS-485 port (optional) | RS-485 port (optional) | RS-485 port (optional) | ||
Safety | Over temp. limit | • | • | • |
Door open alarm | • | • | • | |
Over current limit | • | • | • | |
Aut-run (power failure) | • | • | • |
Product Name |
Temp. & Humid. Chambers |
Temperature & Humidity Chambers |
|||
Model | TH-TG | TH-KE | TH-ME | TH-PE | |
Chamber volume (L) | 180, 314, 419 I 770, 997, 1540 |
189, 302, 408, 800, |
189, 302, 408 | 189, 302, 408 | |
Temp. control |
Operating temp. range |
-5 to 100 / 23 to 212 |
-40 to 150 / -40 to 302 |
-40 to 150 / -40 to |
-70 to 150 / -94 to |
Fluctuation (± °C / °F) |
0.3 / 0.54 |
3.0 / 0.54 |
3.0 / 0.54 |
3.0 / 0.54 |
|
Variation (± °C / °F) |
0.5 / 0.9 |
0.5 / 0.9 |
0.5 / 0.9 |
0.5 / 09 |
|
Humid. control |
Operating humid. full |
10 to 95 I 20 to 95 | 25 to 95 | 20 to 95 | 25 to 95 |
Fluctuation (±% RH) | 2.0 at 60% RH / 40 °C |
0.4, 1.0, 2.0 |
0.4 |
0.4 |
|
Variation (±% RH) | 3.0 at 60% RH / 40 °C |
3.0 |
3.0 |
3.0 |
|
Control | Timer | Wait on/off | Wait on/off | Wait on/off | Wait on/off |
Auto-tuning | • | • | • | • | |
Program function | • | • | • | • | |
Computer interface | RS-232 port, RS-485 port (optional) | RS-232 port | RS-232 port | RS-232 port | |
Safety | Over temp. limit | • | • | • | • |
Door open alarm | • | • | • | • | |
Over current limit | • | • | • | • | |
Aut-run (power failure) | • | • | • | • |
Product Name |
Pharmaceutical Stability |
Temperature & Humidity Chambers |
Clean Temp. & |
|
Model | TH-ICH | TH-CR | GC | |
Chamber volume (L) | 300, 760 |
270 |
300, 1000 | |
Temp. control |
Operating temp. range |
-5 to 85 / 23 to 185 |
-35 to 100 / -31 to 212 |
-5 - 50 / 41 - 122 Lamp off |
Fluctuation (± °C / °F) |
0.3 / 0.54 |
0.5 / 0.9 |
0.1 / 0.18 |
|
Variation (± °C / °F) |
0.5, 0.7 / 0.9, 1.3 |
0.5 / 0.9 |
0.8 / 1.43 |
|
Humid. control |
Operating humid. full |
20 to 85 | 30 to 90 | 40 to 90 |
Fluctuation (±% RH) |
3.0 |
3.0 |
0.4 |
|
Variation (±% RH) |
5.0 |
3.0 |
- |
|
Control | Timer | Wait on/off | Wait on/off | Wait on/off |
Auto-tuning | • | • | • | |
Program function | • | • | • | |
Computer interface |
RS-232 port |
RS-232 port | - | |
RS-485 port (optional) |
RS-485 port (optional) | - | ||
Safety | Over temp. limit | • | • | • |
Door open alarm | • | • | • | |
Over current limit | • | • | • | |
Aut-run (power failure) | • |