Feedwater enters the unit and passes through the activated carbon adsorption media where chlorine and dissolved organics are removed. Periodically, the media is backwashed to remove any accumulated particulate matter. This process is fully automatic.
|
PICF7 |
PICF12 |
PICF22 |
PICF30 |
PICF50 |
PICF90 |
PICF120 |
Flowrates: (m³/hr) |
|||||||
Maximum service |
3.1 |
4.5 |
10.6 |
13.2 |
17.6 |
26.2 |
36 |
Minimum service |
1.6 |
2.3 |
5.3 |
6.6 |
8.8 |
13.1 |
18 |
Maximum effluent |
2.9 |
3.7 |
8.4 |
10.5 |
14 |
19.2 |
19.2 |
Connections - BSP* (inches) |
|||||||
Inlet |
1 ½ |
1 ½ |
2 |
2 |
2 |
3 |
3 |
Outlet |
1 ½ |
1 ½ |
2 |
2 |
2 |
3 |
3 |
Drain |
1 |
1 |
2 |
2 |
2 |
3 |
3 |
Dimensions: (mm) |
|||||||
Filter height |
1775 |
1980 |
2350 |
2450 |
2450 |
3000 |
3500 |
Filter diameter |
554 |
625 |
942 |
1054 |
1219 |
1429 |
1429 |
Weight: (kg) |
|||||||
Shipping |
115 |
175 |
355 |
480 |
630 |
950 |
1300 |
Working |
421 |
624 |
1419 |
1797 |
2386 |
3569 |
4902 |
Services: |
|
Electrical |
230 volts 50Hz single phase |
Feedwater pressure |
2-6 bar |
Feedwater temperature |
1-49°C |
Drain |
Suitable drain for effluent flows at floor level |
* British Standard Pipe - Adaptors are available to convert to equivalent metric size. Contact SUEZ
for details.
For general water conditioning a trace amount of chlorine or chlorine derivatives will remain. For applications requiring chlorine free residuals, please contact SUEZ.
|
PCF10 |
PCF15 |
PCF20 |
PCF30 |
PCF40 |
PCF50 |
PCF70 |
PCF90 |
PCF130 |
PCF200 |
PCF250 |
Flowrates (m3/hr) |
|||||||||||
Maximum service @ 3 minutes contact time * |
1.0 |
1.5 |
2.0 |
3.0 |
4.0 |
5.0 |
7.0 |
9.5 |
13.5 |
20.5 |
25.0 |
Maximum service @ 12 minutes contact time ** |
0.5 |
0.8 |
1.0 |
1.5 |
2.0 |
2.5 |
3.5 |
4.8 |
6.8 |
10.25 |
12.5 |
Pressure drop @ MAX service flow (psi) |
6 |
8 |
10 |
12 |
12 |
18 |
10 |
13 |
9 |
13 |
17 |
Regeneration |
|||||||||||
Backwash flowrate (m3/hr) @ 10ºC |
0.8 |
0.9 |
1.2 |
1.6 |
2.2 |
2.7 |
4.0 |
5.5 |
7.9 |
11.4 |
13.7 |
Effluent volume (m3) |
0.3 |
0.3 |
0.5 |
0.7 |
0.9 |
1.1 |
1.6 |
2.2 |
3.2 |
4.5 |
5.5 |
Connections - BSP (inches) |
|||||||||||
Inlet |
1 |
1 |
1 |
1 |
1 |
1 |
1.5 |
1.5 |
2 |
2 |
2 |
Outlet |
1 |
1 |
1 |
1 |
1 |
1 |
1.5 |
1.5 |
2 |
2 |
2 |
Drain |
0.5 |
0.5 |
0.5 |
0.5 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
Dimensions (mm) |
|||||||||||
Height (incl.control valve) |
1130 |
1600 |
1880 |
1880 |
1990 |
2060 |
2255 |
2175 |
2170 |
2570 |
2570 |
Diameter |
316 |
345 |
372 |
425 |
491 |
550 |
625 |
785 |
936 |
1387 |
1540 |
Weight (Kg) |
|||||||||||
Shipping |
44 |
72 |
100 |
127 |
184 |
239 |
337 |
490 |
718 |
1098 |
1421 |
Working |
75 |
124 |
173 |
224 |
318 |
406 |
580 |
816 |
1180 |
1809 |
2410 |
Services |
|
Electrical *** |
24 V, 50Hz |
Feed water pressure |
2 - 6 Bar |
Feed water temperature |
1 - 35ºC |
Drain |
Sized to accomodate backwash flowrate and c/w air gap in compliance with current regulations |
Notes:
* For free chlorine reduction
** For combined chlorine reduction
*** A separate trasnformer will be required if powered directly from the electrical mains supply. Contact SUEZ for details.