LabMax is appropriate for anyone who needs to analyze and monitor laser output. Data analysis can be achieved via statistical and trend analysis and stored in onboard flash memory for future retrieval with the File Manager tool. Data can also be analyzed directly on a PC through USB and RS-232 serial connections, or by logging data to a USB flash drive attached directly to the meter. Installable applications software and LabView ® drivers are provided to support PC interfacing. The LabMax display and meter can be positioned at many different angles so customers can place it within the limited bench space typically available in a laser lab and still easily view the display.
LabMax-TOP is directly compatible with most Coherent thermal, pyroelectric and semiconductor sensors and displays beam position for quick and accurate setup. These sensors offer wavelength coverage from 190 nm to 12 µm, measure from nW to kW, nJ to J, and from single shot to 10 kHz.
Pièce |
Nom |
Description |
1104620 |
LabMax-TOP avec GPIB |
Compteur d’énergie et de puissance laser avec GPIB |
Nom |
LabMax-TOP avec GPIB |
Résolution de la mesure |
0,1 % de l’échelle totale |
Displayable Resolution |
3 or 4 digits pyroelectric; 3, 4 or 5 digits thermopile and optical (user selectable) |
Measurement Range |
Sensor dependent - reference sensor specifications |
Précision - système |
Précision du compteur + précision du capteur |
Précision - sortie analogique |
±1,0 % |
Précision - compteur numérique |
±1.0% ±2LSD |
Uncertainty |
±1,0 % |
Taux d’échantillonnage de puissance |
10 Hz |
Max Repetition Rate (Hz) |
10,000 sampling (1,000 every pulse) |
Min. Positional Resolution |
0.1 mm |
Affichage |
112x78 mm backlit graphic LCD, 480x320 pixels. Adjustable contrast and viewing angle. |
Statistical Analysis |
Min., max., mean, range, standard deviation, energy dose, and stability. Trend charting, tuning, positional display, and analysis of beam stability |
Computer Interface |
GPIB, USB and RS-232 |
Trigger |
External trigger or internal trigger (2-20% of full scale, selectable) |
Analog Output |
0 to 1, 2 or 4 VDC (selectable) |
Analog Output Update Rate |
Up to 1,000 Hz for pyroelectric; 10 Hz for thermopile and optical |
Temperature (Operating) |
5°C to 40°C (41°F to 104°F) |
Temperature (Storage) |
-20°C to 70°C (-4°F to 158°F) |
Battery Life |
8 hours backlight off (4400 mAh Li-ion battery) |
Instrument Power |
90 to 260 VAC, 50/60 Hz AC power adapter (incl.) |
Size (H x W x D) |
53 x 229 x 152 mm (2.1 x 9.0 x 6.0 in.) |
Weight |
1.04 kg (2.3 lbs.) |
Conforme à la directive RoHS |
Yes |
Référence |
1104620 |
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.