Red Star Vietnam Co., Ltd.
Icons giỏ hàng Cart 0
Total : đ

LeveLine-Mini: Titanium SDI-12 level and temperature sensor

State: In stock
The LeveLine-Mini is a water level and temperature measuring sensor that has been specifically designed to reduce your monitoring costs. It is constructed using titanium and features sensitive pressure and temperature sensors.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

A quick introduction to the LeveLine-Mini

 

LeveLine-Mini Full Feature List

  • High quality titanium body
  • Features a Delrin nose cone
  • Uses the same Piezoresistive pressure sensor found in the LeveLine for highest accuracy
  • Impressive accuracy of 0.1% FS
  • Sensor can log as fast as 10 times per second
  • Cable is hard wired into the sensor, various lengths available to suit every deployment
  • SDI-12 / Modbus output as standard
  • Sensors come with a 2 year warranty
 
 

LeveLine-Mini as part of the LeveLine-EWS  Package

IMG_7662

 

The LeveLine-Mini is the level sensor used in the Early Warning System to alert for rising water levels.

The clever AquaTelemetry system features a built in pressure sensor meaning the level data recorded by the system is fully compensated for changes in barometric air pressure.

 
 

 

Connect to any SDI-12 datalogger or telemetry device

The LeveLine-Mini has SDI-12 and Modbus (RS485) outputs as standard meaning you can connect this sensor to any established monitoring platform that accepts these protocols.

GENERAL

 

  LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Temperature ranges Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Diameter 22.2mm (0.875 in) 22.2mm (0.875 in) 22.2mm (0.875 in) 22mm 22mm
Length 186mm (7.32 in) 186mm (7.32 in) 87mm (3.43 in) 260mm 146mm
Weight 150g (5.3oz) 160g (5.6oz) 120g (4.2oz) 250g 210g
Materials Titanium body, Delrin nose cone Stainless Steel body, Delrin nose cone Stainless Steel body, Delrin nose cone Titanium body, Delrin nose cone Titanium body, Delrin nose cone
Output options Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary
Battery type & life 3.6V lithium; up to 10 years (see note 1) 3.6V lithium; up to 10 years (see note 1) N/A 3.6V lithium; up to 10 years (see note 1) N/A
External power 6 – 30 VDC 6 – 30 VDC 6 – 30 VDC 6 – 24 VDC 6 – 24 VDC

 

MEMORY

 

  LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Size 8.0 MB 2.0 MB N/A 8.0 MB N/A
Data records 500,000 150,000 N/A 500,000 N/A
Log types Linear, Event & User-Selectable
Schedule with Future Start, Future Stop,
Deploy Start and Real Time View
Linear, Event & User-Selectable
Schedule with Future Start, Future Stop,
Deploy Start and Real Time View
N/A Linear, Event & User-Selectable Schedule with Future
Start, Future Stop, Deploy Start and Real Time View
N/A
Fastest logging rate & Modbus rate 10 per second 1 per minute (logging)
5 per second (Modbus)
10 per second (Modbus Rate) 1 per second 1 per second
Fastest SDI-12 output rate 1 per second 1 per second 1 per second 1 per second 1 per second
Real-time clock Accurate to 1 second/24-hr period (± 6 minutes/year) Accurate to 1 second/24-hr period (± 6 minutes/year) N/A Accurate to 1 second/24-hr period (± 6 minutes/year) N/A

 

SENSOR

 

  LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Type / Material Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic
Range (Absolute) 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) 0 to 16.7 psi; 0 to 1.15 bar 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Range (Gauge) 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) N/A N/A 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Maximum pressure Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range
Accuracy (FS) (see note 3) ±0.05% FS ±0.1% FS ±0.05% FS ±0.05% FS ±0.05% FS
Accuracy (FS) (See note 2) ±0.1% FS ±0.2% FS ±0.1% FS ±0.1% FS ±0.1% FS
Resolution 0.005% FS or 1mm whichever is greater 0.1mb 0.005% FS or 1mm whichever is greater 0.002% FS or 1mm whichever is greater 0.002% FS or 1mm whichever is greater
Units of measure Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink

 

ELECTRICAL CONDUCTIVITY

 

  LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Range N/A N/A N/A 0 – 200mS/cm (0 – 200,000µS/cm) 0 – 200mS/cm (0 – 200,000µS/cm)
Resolution N/A N/A N/A 1µS 1µS
Accuracy N/A N/A N/A ± 1% reading or ±1µS whichever is greater (see note 5) ± 1% reading or ±1µS whichever is greater (see note 5)

 

SALINITY (note 4)

 

  LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Range N/A N/A N/A 0 – 70 PSU / 0 – 70 ppt (g/Kg) 0 – 70 PSU / 0 – 70 ppt (g/Kg)
Resolution N/A N/A N/A 0.01PSU / 0.01 ppt 0.01PSU / 0.01 ppt
Accuracy N/A N/A N/A ±1% reading or ± 0.1 unit if greater ±1% reading or ± 0.1 unit if greater

 

TEMPERATURE SENSOR

 

  LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Accuracy Resolution ±0.1° C
0.01° C
±0.1° C
0.01° C
±0.1° C
0.01° C
±0.1° C; 0.01° C ±0.1° C; 0.01° C
Units of measure Celsius Celsius Celsius Celsius (fahrenheit available in LeveLink) Celsius (fahrenheit available in LeveLink)

 

WARRANTY

 

  LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Standard N/A N/A N/A 2 years 2 years
Extended N/A N/A N/A Options Available Options Available

 

Notes: 1) Dependent on logging rate. 2) Across factory-calibrated pressure range at a constant temperature. 3) Across factory-calibrated pressure and temperature ranges. 4) Readings calculated from EC and temperature values. 5) At the calibration point at 25°C

  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.