Distillation is used to separate liquid mixtures made up of individual liquids
that are soluble in one another.
EDIBON's distillation unit, in its different versions, is one of the most powerful
laboratory tools for the study of the variables that affect the distillation process.
The student can investigate the principles that rule the mass and energy transference,
as well as determine the optima operation point to carry out a big quantity of separations.
This unit is basically composed by a boiler on which two types of interchangeable columns
can be adapted (plate columns and Raschig
Rings column), a reflux system and a tank for the distillation.
The steam that goes to the head of the column is sent to a total condenser. The cooling
water flow that crosses the condenser is regulated and indicated in a flow sensor.
The pressure loss in the column can be measured with a pressure sensor.
The temperatures of the system are measured by sensors placed in strategic positions.
This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA),
and includes: The unit self + a Control
Interface Box + a Data Acquisition Board + Computer Control, Data Acquisition and
Data Management Software Packages, for controlling the process and all parameters involved in the process.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

Key features:

 

● Advanced Real-Time SCADA and PID Control.
● Open Control + Multicontrol + Real-Time Control.
● Specialized EDIBON Control Software based on Labview.
● National Instruments Data Acquisition board (250 KS/s , kilo samples per second).
● Calibration exercises, which are included, teach the user how to calibrate a sensor and the importance of checking the accuracy of the sensors before taking measurements.
● Projector and/or electronic whiteboard compatibility allows the unit to be explained and demonstrated to an entire class at one time.
● Capable of doing applied research, real industrial simulation, training courses, etc.
● Remote operation and control by the user and remote control for EDIBON technical support, are always included.
● Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).
● Designed and manufactured under several quality standards.
● Optional CAL software helps the user perform calculations and comprehend the results.
● This unit has been designed for future expansion and integration. A common expansion is the EDIBON Scada-Net (ESN) System which enables multiple students to simultaneously operate many units in a network.

 

 

EDIBON SCADA System
and PID CONTROL included
Control
Interface Box
Data
Acquisition
Board
Software for:
- Data Acquisition
- Data Management
- Computer Control
Computer
(not included
in the supply)
Cables and Accessories Manuals Unit: UDDC. Batch Distillation Unit

 

 

Process diagram and Unit elements allocation:

 

 

 

 

Exercises and Practical possibilities to be done with main items:

 

1.- Preparation of solutions.
2.- Analytic valuation techniques.
3.- Filling of the column.
4.- Batch operation.
5.- Obtaining the McCabe-Thiele diagram. Without reflux.
6.- Obtaining the number of plates. Without reflux.
7.- Efficiency calculations. Without reflux.
8.- Variation of the composition of the distilled product: constant reflux ratio.
9.- Constant composition of the distilled product: variation of reflux ratio.
10.- Constant composition of the distilled product: constant reflux ratio.
11.- Mass and energy balances across the system.
12.- Plates fluid dynamics studies, including load loss and column flooding.
13.- Calculation of the theoretical number of floors in the plates columns, and the equivalent height of

the theoretical floor (HEPT) in the Raschig rings columns.
14.- Pursuit of the temperatures in all plates in the column (Plates columns).
15.- Study of the rectification efficiency.
16.- Demonstration of azeotropic distillation.
17.- Work different heating contribution with regulation by the computer.
18.- Studies of heating interchange in glass refrigerators.

Additional practical possibilities:


19.- Temperature sensors calibration.
20.- Flow sensor calibration.
21.- Pressure sensor calibration.Other possibilities to be done with this Unit:
22.- Many students view results simultaneously.
To view all results in real time in the classroom by means of a projector

or an electronic whiteboard.
23.- Open Control, Multicontrol and Real Time Control. This unit allows intrinsically

and/or extrinsically to change the span, gains; proportional, integral, derivate

parameters; etc, in real time.
24.- The Computer Control System with SCADA and PID Control allow a real

industrial simulation.
25.- This unit is totally safe as uses mechanical, electrical and electronic,

and software safety devices.
26.- This unit can be used for doing applied research.
27.- This unit can be used for giving training courses to Industries
even to other Technical Education Institutions.
28.- Control of the UDDC unit process through the control interface
box without the computer.
29.- Visualization of all the sensors values used in the UDDC unit process.
- By using PLC-PI additional 19 more exercises can be done.
- Several other exercises can be done and designed by the user.

Required services:

 

- Electrical supply: single-phase, 220V/50Hz or 110V/60Hz.
- Water supply.
- Computer (PC).

 

 

Dimensions & weights:

 

Unit

Dimensions: 900 approx. x 600 x 2600 mm. (35.43 x 23.62 x 102.36 inches approx.)

Weight: 170 Kg. approx. (375 pounds approx.)

Control Interface Box

Dimensions: 490 x 330 x 310 mm. approx. (19.29 x 12.99 x 12.20 inches approx.).

Weight: 10 Kg. approx. (22 pounds approx.).