1.-Determination of the inlet power, heat produced and performance coefficient. Air as heat source.
2.- Preparation of performances curves of the unit whit different inlet and outlet temperatures. Air as a heat source.
3.- Lay out of the steam compression cycle in a diagram P-H and comparison with the ideal cycle. Air as heat source.
4.- Preparation of the performance curves of the unit based on the properties of the refrigerant and at different condensation and evaporation temperatures. Air as heat source.
5.- Energy balances.
Other possible practices:
6.- Temperature sensors calibration.
7.- Flow sensors calibration.
8.- Pressure sensors calibration.
9-27.- Practices with PLC.
1. THA2AC. Unit:
Bench-top unit. Anodized aluminium structure and panels in painted steel.
Diagram in the front panel with similar distribution to the elements in the real unit.
Cooling compressor, computer controlled. Air condenser, computer controlled. Water condenser. Air evaporator, computer controlled. High pressure control. Coolant accumulation tank. Cooling filter. Expansion valve. Tank of division of the cooling liquid. 4 Manometers.
9 Temperature sensors (4 sensors measure the cooling temperature, 2 sensors measure the water temperature and 3 sensors measure the air temperature).
2 Flow sensors: cooling flow sensor and water flow sensor (water condenser).
2 Pressure sensors: cooling pressure sensor (compressor outlet) and cooling pressure sensor (compressor inlet).
Wattmeter.
Enthalpy diagram of the refrigerant R134a.
2. THA2AC/CIB. Control Interface Box:
With process diagram in the front panel. The unit control elements are permanently computer controlled. Simultaneous visualization in the computer of all parameters involved in the process. Calibration of all sensors involved in the process.
Real time curves representation. All the actuators’ values can be changed at any time from the keyboard. Shield and filtered signals to avoid external interferences. Real time control with flexibility of modifications from the computer keyboard of the parameters, at any moment during the process. Open control allowing modifications, at any moment and in real time, of parameters involved in the process. 3 safety levels: mechanical in the unit, electronic in the control interface, and the third one in the control software.
3. DAB. Data Acquisition Board:
PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog inputs. Sampling rate up to:
250 KS/s. 2 Analog outputs. 24 Digital Inputs/Outputs.
4. THA2AC/CCSOF. Computer Control+Data Acquisition+Data Management Software:
Flexible, open and multicontrol software. Management, processing, comparison and storage of data. Sampling velocity up to 250,000 data per second. It allows the registration of the alarms state and the graphic representation in real time.
5. Cables and Accessories, for normal operation.
6. Manuals: This unit is supplied with 8 manuals.
Dimensions (approx.) =Unit: 900 x 600 x 500 mm. Weight: 85kg.
Control Interface: 490 x 330 x 310 mm. Weight: 10 Kg.
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.