1.- Obtaining of the curve of thermal conductivity of the air.
2.- Thermal conductivity in vacuum.
3.- Water thermal conductivity determination.
4.- Thermal conductivity determination of a mineral oil.
5.- Calibration of the Unit.
6.- Control system: Calibration of the sensors. Other possible practices:
7.- Dry air thermal conductivity under atmospheric pressure.
8-26 .- Practices with PLC.
1. TCLGC. Unit:
Anodized aluminium structure and panel in painted steel. Diagram in the front panel with similar distribution to the elements in the real unit.
Aluminium body (cylinder) with brass jacket that contains the test fluid and the refrigeration water. Variable heating resistance
(in the cylinder), computer controlled. The power is measured by a sensor.
6 Temperature sensors. Water flow sensor.
2. TCLGC/CIB. Control Interface Box:
With process diagram in the front panel. The unit control elements are permanently computer controlled. Simultaneous visualization in the computer of all parameters involved in the process. Calibration of all sensors involved in the process. Real time curves representation. All the actuators’ values can be changed at any time from the keyboard. Shield and filtered signals to avoid external interferences. Real time PID control with flexibility of modifications from the computer keyboard of the PID parameters, at any moment during the process. Open control allowing modifications, at any moment and in real time, of parameters involved in the process. 3 safety levels: mechanical in the unit, electronic in the control interface, and the third one in the control software.
3. DAB. Data Acquisition Board:
PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog inputs. Sampling rate up to:
250 KS/s. 2 Analog outputs. 24 Digital Inputs/Outputs.
4. TCLGC/CCSOF. PID Computer Control+Data Acquisition+Data Management Software:
Flexible, open and multicontrol software. Management, processing, comparison and storage of data. Sampling velocity up to 250,000 data per second. It allows the registration of the alarms state and the graphic representation in real time.
5. Cables and Accessories, for normal operation.
6. Manuals: This unit is supplied with 8 manuals.
Dimensions (approx.) = Unit: 500 x 400 x 300 mm. Weight: 40kg.
Control Interface: 490 x 330 x 310 mm. Weight: 10 Kg.
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.