TMA is the measurement of a change of a dimension or a mechanical property of the sample while it is subjected to a temperature regime.

TMA uses interchangeable probes at varied loads to make a number of measurements, including the softening temperature or glass transition temperature, tensile modulus, compression modulus, the thermal expansion, melting temperature, crystalline phase transition temperature, crystalline to amorphous transition temperatures, and creep under load, by measuring the change of a dimension of a material.
Warranty: 12 tháng


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

● High-sensitivity, high-precision measurement by the differential method

● Multi-measurement system that excels in expandability

● Flexible handling of various sample sizes

● Notable enhancement of heating and cooling rates enabled by a compact electric furnace

● Simple sample setting mechanism, the first of its kind in differential TMA

● Safety foremost emphasized on the entire system

● Different measurement methods

     + Compression loading method

     + Tensile loading method

     + Penetration method

     + High-sensitivity differential penetration method

● Measuring temp. range

     + Standard model: Ambient to 1100°

     + High-temperature model: Ambient to 1500°

Measurement mode Compression loading*1 Tensile loading Penetration
Type Standard High temperature Penetration High sensitivity differential penetration method
Detection system Differential expansion Non-differential expansion Differential expansion
Standard sample size 5 mm diameter (max 9 mm diameter) Thickness: 10 - 200 µm   5 mm diameter
Length: 10 - 20 mm Length: 10, 15, 20 mm; width: 5 mm   Thickness: 4 mm (max)
Material SiO2 Al2O3 SiO2
Maximum load 1000 mN
Measurement temperature range*2 Ambient to 1100°C Ambient to 1500°C Ambient to 600°C
Maximum heating rate 100°C/min (low temperature furnace: 20°C/min)
Measurement range (FS) 5000 µm
Loading mode
  1. Constant loading (up to 1000 mN in the shrinkage or tension direction, 1 mN step)
  2. Constant-rate loading (up to 1000 mN in the shrinkage or tension direction at a rate of 1 - 500 mN/min)
  3. Sine-wave cyclic (oscillating from 1 - 1000 mN and a frequency of 0.01 - 1 Hz)
Measurement atmosphere Air, inert gas or gas flow

 

 

*1  The specifications of the high sensitivity three-point bending method conform with the standard model for compression loading mode
*2  Option: low temperature furnace: -150°C to 600°C; Liquid nitrogen auto feed type cooling attachment: -150°C to 600°C

 

 

Software:

 

1. Measurement data protection function
    During measurement, when a connection error occurs between the station and the module, the module will continue to perform

    the on-going measurement and the data will be stored in the module. The stored data is retrieved using a PC after the measurement,

    protecting valuable measurement data.

 

2. End operation settings function
    The ECO mode or power OFF can be selected after the end of measurement. The temperature and time condition can be specified.
    We can select a variety of operation condition of the attached forced air-cooling fan such as cool up to room temperature, not in use

    on continuous usage.

 

3. ECO mode
     After completing measurement, the ECO mode can be selected in the stand-by condition reducing the electricity consumption.

    Especially in TG-DTA, the ECO mode facilitates immediate transition from stand-by to stable measurement conditions.

 

4. First aid function
     When an error or problem occurs in the module, the error number, error description as well as troubleshooting measures will be displayed

     facilitating a quick and smooth recovery condition. Also the error contents are stored in log files and can be readily sent to the technical service

     department for an immediate appropriate response.

 

5. ASCII data import function
    Using the conversion software, the Thermo plus EVO2 analysis software can analyze carious ASCII converted measurement data.

 

6. E-mail function
    The Thermo plus EVO2 can transmit information by email such as end of measurement, measurement data, occurrence of an error to PC,

     mobile phones thru corporate LAN connection abs can confirm the condition of an on-going measurement at remote locations.

 

7. Excel, Word output
     From the menu directly, the measurement file can be directly exported in Word or Excel. Also, the output style can be modified thru the layout

     editing function. When exporting data in Excel, the numerical data will be automatically created in the worksheet 2 allowing a convenient data

     analysis in other application software.

 

8. Instrument usage history listing function
    This function automatically records the module’s usage. Information such as date of usage, module name, operator, temperature program and

    measurement results are filed and saved in the achieve list. The history use of the module and the time of use are clear and effective for

    management and maintenance.

  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.