Notice: Undefined index: en in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0

Warning: Invalid argument supplied for foreach() in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0
A-series (High grade range)
Red Star Vietnam Co., Ltd.
Icons giỏ hàng Cart 0
Total : đ

A-series (High grade range)

State: In stock
A wider range of test requirements and higher test specifications.
A-series meets the needs for such a versatile test environment.
Advanced automatic energy saving, high level of functionality and a protected test environment.
A series improves the working environment of vibration testing.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

 

 Improvement of performance

Improvement in excitation force.

When compared with the conventional i & J series, the A series increases the relative excitation force.

  • Increased force per system power requirement
  • Increased force per system mass
  • Increased force per system size

 

 

Standard 76.2mmp-p displacement

*Only for A30,A45, A65

A-series has a displacement of 76.2 mmp-p (3 inch stroke) which gives good balance between specification of velocity, acceleration and displacement. This single system can be used in a very wide variety of tests.

Increase in frequency range

A-series has wider frequency range than conventional systems.(Secured stroke of A30, A45 & A65 is 76.2 mmp-p based on mechanical stroke 82 mmp-p)

Cross-axis acceleration reduction

A series dramatically reduces cross-axis (crosstalk) acceleration (horizontal vibration). Highly accurate testing is achieved.

 

High velocity shock testing 

*Only for A30,A45, A65

A-series(EM amplifier model)provides a maximuim of 3.5m/s shock velocity testing which has not been possible with standard conventional systems(i,J-series).

② User friendly and Secure

Lower power consumption

In comparison with the same class of conventional systems (i,J-series), the A-series achieves lower power consumption. With an automatic energy-saving function increased energy saving is achieved across all force ranges.

International safety standards

A-series complies with international safety standards.

 

 User friendly and Secure

Rapid creation of a test from a set of pre-defined templates conforming to most international test standards.

 

Remote monitoring of the test status over the internet.

The status of the test, and the amplifier or shaker operation can be viewed on a remote PC using a standard internet browser. 
Problems or errors are easily identified.

 

 

Các mẫu bàn rung

 

 System ModelA03/SA1MMA10/SA1HMA10/EM1HMA20/SA2HMA20/EM2HM
 Frequency Range(Hz) 0~4000 0~4500 0~3300
System
Specifications
Rated
Force
Sine(kN) 3 10 20
Random
(kNrms)*2)
3 10 20
Shock(kN) 6 20 40
Maximum
Acc.
Sine(m/s2) 1000 900 900
Random
(m/s2rms)
700 630 630
Shock
(m/s2 peak)
2000 1500 1500
Maximum
Vel.
Sine(m/s) 2.0 2.0 2.0
Shock
(m/s peak)
2.3 2.3 2.5
Maximum
Dsp.
Sine(mmp-p) 30 51 51
Maximum Travel
(mmp-p)
40 64 66
Maximum Load(kg) 120 200 300
Power Requirements
(kVA)*1)
8.7 20.4 30
Vibration
Generator
ModelA03A10A20
Armature Mass(Kg) 3 11 22
Armature Diameter(φmm) 128 210 280
Allowable Eccentric
Moment(N・m)
160 294 700
Dimensions(mm)
W×H×D
868×700×500 946×827×676 1038×933×775
Mass(kg) 400 1080 1600
Power
Amplifier
ModelSA1MM-A03SA1HM-A10EM1HM-A10SA2HM-A20EM2HM-A20
Maximum Output(kVA) 5.4 11 11 21 21
Dimensions(mm)
W×H×D
580×1950×850 580×1950×850 580×1950×850 580×1950×850 580×1950×850
Mass(kg) 240 280 330 350 410
ControllerVibration Controller See Vibration Controller K2
CoolingCooling Method Air cooling
BlowerDimensions
(mm)W×H×D
386×882×370 520×1315×891 707×1531×946
Mass(kg) 22 125 190

 

 

 System ModelA30/SA3HMA30/EM3HMA45/SA4HMA45/EM5HMA65/SA6HMA65/EM7HM
 Frequency Range(Hz) 0~2600 0~2600 0~2600 0~2600 0~2600 0~2600
System
Specifications
Rated
Force
Sine(kN) 30 30 45 45 65 65
Random
(kNrms)*2)
30 30 45 45 65 65
Shock(kN) 60 60(50)*6) 90 90(80)*6) 130 130(120)*6)
Maximaum
Acc.
Sine(m/s2) 900 900 900 900 900 900
Random
(m/s2rms)
630 630 630 630 630 630
Sock
(m/s2 peak)
1500 1500 1500 1500 1500 1500
Maximum
Vel.
Sine(m/s) 2.0 2.0 2.0 2.0 2.0 2.0
Shock
(m/s peak)
2.5 2.5(3.5)*6) 2.5 2.5(3.5)*6) 2.5 2.5(3.5)*6)
Maximum
Dsp.
Sine(mmp-p) 76.2 76.2 76.2 76.2 76.2 76.2
Maximum
Travel
(mmp-p)
82 82 82 82 82 82
Maximum Load(kg) 400 400 600 600 1000 1000
Power Requirements
(kVA)*1)
36 36 57 57 83 83
Vibration
Generator
ModelA30A30A45A45A65A65
Armature Mass(Kg) 33 33 50 50 72 72
Armature Diameter
(φmm)
290 290 436 436 446 446
Allowable Eccentric
Moment(N・m)
850 850 1550 1550 1550 1550
Dimensions
(mm)W×H×D
1100x
1048x
840
1100x
1048x
840
1232x
1215x
1040
1232x
1215x
1040
1310x
1253x
1040
1310x
1253x
1040
Mass(kg) 2000 2000 3000 3000 3500 3500
Power
Amplifier
ModelSA3HM-A30EM3HM-A30SA4HM-A45EM5HM-A45SA6HM-A65EM7HM-A65
Maximum
Output(kVA)
31 31 44 44 68 68
Dimensions
(mm)W×H×D
580x
1950x
850
580x
1950x
850
580x
1950x
850
1160x
1950x
850
580x
1950x
850
1160x
1950x
850
Mass(kg) 420 500 900 1000 1000 1150
ControllerVibration Controller See Vibration Controller K2
CoolingCooling Method Air cooling
BlowerDimensions
(mm)W×H×D
707x
1531x
946
707x
1531x
946
1170x
2006x
1033
1170x
2006x
1033
1183x
2006x
1276
1183x
2006x
1276
Mass(kg) 190 190 270 270 420 420
  • *1) Power supply:3-phase 200/220V, 50/60Hz or 3-phase 380/400/415/440V, 50/60Hz.
  • *2) Force ratings are specified in accordance with ISO5344 conditions.
    Please contact IMV or your local distributor with specific test requirements.
  • *3) The specification shows the maximum system performance. For long-duration tests,
    de-rating by up to 70% must be applied. Continuous use at maximum levels may cause failure.
  • *4) In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
  • *5) Frequency range values vary according to sensor and vibration controller.
  • *6) High velocity restricts maximum Shock force.
  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.