Notice: Undefined index: en in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0

Warning: Invalid argument supplied for foreach() in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0
K2
Red Star Vietnam Co., Ltd.
Icons giỏ hàng Cart 0
Total : đ

K2

State: Out of stock
Single controller supports all.

The vibration controller is a unit that faithfully enables and implements the tests that our customers need. IMV has always conducted all the development of all the hardware and software of this important system in-house. IMV strives to make complicated tests easy to do. The K2 system offers enhanced functions and operability based on the most advanced technologies and incorporating feedback from our customers.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

 

User-friendly Interface

[Instinctive Operation]Visualised icons are helpful for operations.

[Simplified definition]General test definitions are executed by following instructions on the screen using “Simplified definition”.

[Help]The enhanced Help screen explains meanings of phrases and gives detailed descriptions of the system.

 

Easy-to-use Functions

[Web monitor]Web monitor allows the user to monitor excitation on screen using a LAN-based PC.

[Report generator]Report generator saves test results and data graphs in Microsoft Word in any layout.

 

Intelligent Control Capabilities
  • K2 employs high-resolution 24 bit A/D and D/A converters to implement intelligent control capabilities.
Enhanced Interlock Function

A hardware mute function immediately cuts off output signals independent of software control.

  • [E-mail notification]Notification of any abnormality during excitation or termination of excitation will be sent to any e-mail addresses desired by the user.
  • [Data saving]The K2 outputs definitions and test results in CSV format.

 

InstallationK2 is compatible both with OA desks and instrument racks

Image of desk instllation : Relaxed operation on a chair

 

Basic Software

Specifications

Optional software

SINE

 

■ Control Algorithm

Swept-sine amplitude is controlled by feedback

■ Control Freq. Range

0.1-20000kHz

■ Control Dynamic Range

More than 114dB

■ Operation Mode

Sweep/Spot/Manual

■ Estimation Method

Average, RMS, Tracking

■ Averaging Method of Control Response

Average control, Max. control,Min.control

■ Number of Chs.

Max.64

*May be affected by other conditions

■ R_DWELL:Resonance Dwell

■ LIMIT CONTROL

■ A_DWELL: Amplitude Dwell

■ Multi Sweep Sine

RANDOM

 

■ Control Algorithm

PSD of random signal closed loop control by spectrum density for each frequency segment

■ Control Freq.

Max.20000kHz

■ Number of Control Lines

Max.25600 lines

■ Control Dynamic Range

More than 94dB

■ Loop Time

200ms (fmas=2000Hz, at L=400line)

■ Averaging Method of Control Response

Average control, Max. control, Min. control

■ Number of Chs.

Max.64

*May be affected by other conditions

■ SOR: Sine on Random

■ ROR: Random on Random

■ PSD LIMIT: PSD limit control

SHOCK

 

■ Control Algorithm

Finite-length waveform control

■ Control Freq. component

Max.20000kHz

■ Number of Control Lines

Max.25600 lines

■ Control Dynamic Range

More than 84dB

■ Reference Waveform

Classical Shock Waveform
(Half-Sine, Haversine, Saw-tooth, Triangle, Trapezoid),
 
SINE Beat/SINE Burst, Measured Waveform,Symmetric Compensation Defined Waveform

■ Number of Chs.

Max.64

*May be affected by other conditions

■ LONG WAVEFORM: Waveform reproduction option
(up to 200k data points)

■ MEGAPOINT: Mega data point option
(up to 5000k data points)

■ SRS: Shock Response Spectrum

 

Basic Software

Specifications

Optional software

BMAC

 

■ Control Algorithm

Finite-length waveform control

(based on feed-forward method)

■ Control Freq.component

Max.20000kHz

■ Number of Control Lines

Max.25600 lines

■ Control Dynamic Range

More than 84dB

■ Reference Waveform

Max.5000k points

■ Number of Chs

Max.64

*May be affected by other conditions

■ ENDURANCE2: Endurance test option

Multi Random

 

■ Control Algorithm

PSD closed loop control of the random signal
spectrum density for each frequency segment.
Real time waveform control
Cross axis motion suppressing control

■ Control Freq. component

Max.10000kHz

■ Number of Control Lines

Max.25600 lines

■ Control Dynamic Range

More than 90dB

■ Loop Time

450ms
(3-input, 3-output control, 120 DOF,
fmax = 2000 Hz, L = 200 line cross-talk
information averaging times = 8times/loop

■ Averaging Method of Control Response

Average control, Max. control, Min. control

■ Number of Chs

Max.64 (Main control channnel is Max.32Chs.)

*May be affected by other conditions

■ PSD LIMITPSD limit control
PSD limit control

Multi Sine

 

■ Control Method

Amplitude Level control of the sweep sine by using feedback
PhaseReal time waveform control of feed-forward method.
cross axis motion suppressing control

■ Control Freq.

0.1 10,000 Hz

■ Freq. Resolution

Less than 10-4 of freq.

■ Control Dynamic Range

More than 114 dB

■ Operation Mode

1) Continuous sweep, Spot test
2) Usable physical quantity
response signal

■ Number of Chs

Max. 64 channels Main control channnel is Max.32Chs.

*May be affected by other conditions

■ Limit Control

 

 

Console

Number of Slots

3 (Move slots can be incereased by additional consoles)

AC Power

Single-phase AC, 100V-240V (Auto-selected)

Extension

Connection among the unit cases (Providing support for large-scale systems)

External Communication

Contact I/O (for Emergency stop)

Ambient Conditions

0-40, below 85% RH, no condensation

Dimensions

430(W)x100(H)x340(D)mmProtruding part not included

Mass

6.0Kg (Approx.)

8 ch. Input Module

Number of Chs.

8

Input Terminal

BNC

Input Signal

Charge,Voltage,IEPE

Charge Amp. Sensitivity

1.0mV/pC or 10mV/pC

Charge Amp. Cut-off

0.32Hz

Max. Input

Charge Input ±10000pC or ±1000pC

Voltage Input ±10000mV

IEPE Input ±10000mV

Sampling Frequency

Max. 51.2kHz

Coupling

AC or DC

Cut-off at AC Coupling

0.1Hz

CCLD AmplifierIEPE)

+24VDC,3.5mA

TEDSIEPE)

Ver0.9,Ver1.0

A/D Converter

Method : ΔΣmethod

Resolution : 24-bit

Dynamic Range: 117dB

Digital Filter : Ripple in pass band ±0.001dB

       : Rejection band attenuation quantity 110dB

4 ch.Input and 4 ch.Output Module

Input part

Number of Chs.

4

Input Terminal

BNC

Input Signal

Charge, Voltage, IEPE

Charge Amp. Sensitivity

1.0mV/pC or 10mV/pC

Charge Amp. Cut-off

0.32Hz

Max. Input

Charge Input ±10000pC or ±1000pC

Voltage Input ±10000mV

IEPE Input ±10000mV

Sampling Frequency

Max. 51.2kHz

Coupling

AC or DC

Cut-off at AC Coupling

0.1Hz

CCLD AmplifierIEPE)

+24VDC,3.5mA

TEDSIEPE)

Ver0.9,Ver1.0

A/D Converter

Method : ΔΣmethod

Resolution : 24-bit

Dynamic Range: 117dB

Digital Filter : Ripple in pass band ±0.001dB

       : Rejection band attenuation quantity 110dB

Output part

Number of chs.

4(a channel is occupied for drive output)

Output Terminal

BNC

Output Signal

Voltage

Max. Output

±10000mV

Sampling Freq.

Max. 51.2kHz

D/A Converter

Method : ΔΣmethod

Resolution : 24-bit

Dynamic Range: 120dB

Digital Filter : Ripple in pass band ±0.005dB

       : Rejection band attenuation quantity 75dB

 

 

Common options

Outline

CAPTURE

Analogue waveform signal data program

Captures an analogue wave signal, saves the signal as waveform data to use for the reference of SHOCK,BMAC,waveform controls or Random vibration PSD control.

■ Sampling Freq.: Max.51200Hz

■ Data Length: Max.5000k points

■ Number of Chs. : Max.64

■ Waveform edit/analysis function : Filtering, Frequency Transfer processing, PSD transfer, Transmissibility ratio between channels

SCHEDULER : Test scheduler

Scheduling and execution of defined tests.

Integrated Control System

In a combined simulation system, a single PC controls, defines, and executes tests and schedules for vibration simulation systems and the temperature/humidity climatic test chamber.

 

 

Required Specification of the PC for K2 without Energy Manager ISM-EM
● Microsoft Windows 7 Professional (32bit / 64bit)
 (Windows XP Professional SP3(32bit) is also acceptable.)
● Faster CPU than Intel Core2Duo 2.0GHz is recommended
● CD-ROM Drive (necessary at installation)
● 2GB main memory resource for the application software
● One Built-in PCI Express x1 slots

  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.