Notice: Undefined index: en in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0

Warning: Invalid argument supplied for foreach() in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0
Directional/Non Directional Overcurrent Protection Relay Module - ERP-SDND
Red Star Vietnam Co., Ltd.
Icons giỏ hàng Cart 0
Total : đ

Directional/Non Directional Overcurrent Protection Relay Module - ERP-SDND

State: Out of stock
ERP-SDND. Directional/Non Directional Overcurrent Protection Relay Module, for use with the Protection Relays Test Unit (ERP-UB), to enable investigations into protection and monitoring of generator and transformer
schemes, overhead lines, underground cables and backup on high-voltage systems.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

Practical possibilities:

 

1.- Verification of Directional Protectionfunctionality.
2.- Directional Protection with different measurement circuit conditions.
3.- Directional Protection application to Transmission Line under different load conditions.
4.- Forward Directional Protection.
5.- Reverse Directional Protection.
6.- Non-Directional Overcurrent Protection.
7.- Residual Ground Time-OvercurrentProtection.

8.- Residual Ground Instantaneous Overcurrent Protection.
9.- Verification of Cable Undervoltage Protection.
10.- Verification of Cable Overvoltage Protection.
11.- Verification of Current TransformersMeasurements accuracy.
12.- Verification of Voltage TransformersMeasurements accuracy.
13.-Distribution System Directional Protection.

The main functions: The ERP-SDND Unit includes numerous phase, negative-sequence, residual-ground, and neutral overcurrent elements, as shown in the next table:

 

Overcurrent Element
Operating Quantity

Number of
Elements

Directional
Contro

Torque
Control

Definite-Time
Delay

Maximum phase
current
(IA, IB, or IC)

1 inverse-time
(51P)
6 instantaneous
(50P1-50P6)

Yes
Yes, on first 4

Yes
Yes, on first 4

NA
Yes, on first 4

Maximum
phase-phase current
(IAB, IBC, or ICA)

4 instantaneous
(50PP1-50PP4)

No No  No 

Independent phase
current

3 inverse-time
(51A, 51B, 51C)

Yes Yes NA

Residual-ground
current (3I0)

2 inverse-time
(51G1,51G2)
6 instantaneous
(50G1-50G6)

Yes
Yes, on first 4

Yes
Yes, on first 4

NA
Yes, on first 4

Negative-sequence
current (3I2)

1 inverse-time
(51Q)
6 instantaneous
(50Q1-50Q6)

Yes
Yes, on first 4

Yes
Yes, on first 4

NA
Yes, on first 4

Neutral current
(IN)

1 inverse-time
(51N)
6 instantaneous
(50N1-50N6)

Yes
Yes, on first 4

Yes
Yes, on first 4

NA
Yes, on first 4

 

 

Inverse-time overcurrent element settings include a wide and continuous pickup current range, continuous time-dial setting range, and timecurrent curve choices from both US (IEEE) and IEC standard curves.

Undervoltage Protection Element (27).
Phase Overvoltage Protection Element (59P).
Ground Overvoltage Protection Element (59G).
Negative Sequence Overvoltage Protection (59Q).
Creating fault and disturbance records.
Selectable blocking.
Selogic Control Equations.
Event Report.
Sequential Events Recorder (SER).
Breaker Wear Monitor.
Station Battery Monitor.
DNP3 Serial LAN/WAN Outstation (Slave).
Modbus RTU and TPC.
High-Accuracy Metering.
Remote and Local Control Switches.
Wye or Delta Voltage Connection.
Synchrophasor Measurements.
Fault Locator.
Fast SER Protocol.
Directional/Definite-Time Overcurrents Elements.
Two Residual-Ground Time-Overcurrents Elements.
Six Frequency Elements.
Sensitive Earth Fault Protection and Directional Protection for Various
System Grounding Practices.
Load-Encroachment Logic.
Synchronism Check.
ACSELERATOR QuickSet Compatible.

The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay.
It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays.
Cables and Accessories, for normal operation.
Manuals: This unit is supplied with 8 manuals.
Dimensions(approx.): 490 x 330 x 310 mm. Weight: 10 Kg.

  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.