Notice: Undefined index: en in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0

Warning: Invalid argument supplied for foreach() in /var/www/html/redstarvietnam.com/public_html/core/functions/function_global.php on line 0
Enviromental Test Chamber
Red Star Vietnam Co., Ltd.
Icons giỏ hàng Cart 0
Total : đ

Enviromental Test Chamber

State: In stock
Replication of Combined Environmental Stress

Industrial products are always exposed to environmental impacts, which are "climate" and "physical" environmental impacts. These are not separately impacting, but in intricately intertwined way as a combined stress. We offers temperature and humidity chamber with vibration test systems and meet the customer's requests immediately.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

Centralized control system

By adopting a centralized control system, it can control whole system not only vibration, but also temperature and humidity.

 

Various option

We can offer a variety of options such as a side door, a back door and a see-through door.

 

Chamber base direct coupling method

IMV vibration test systems as of i , J , VS series ( with some exceptions) employ Direct Coupling to dock the vibration generators to the chambers. It eliminates troublesome works of connection shaft replacement and loss of excitation force. It also eliminate necessity of specimen remount in the chamber.

 

Moving attachment for shaker

Shaker and chamber can be separately used moving smoothly on rails.

 

 

Items needed for selection of Temperature/Humidity Chambers

Presents of information about following items are requested for estimation.

 

Working volume

Working volume size meeting to your specimen size

 

Temperature range

Upper temperature limit and lower temperature limit fulfilling the conditions of the projected tests

 

Humidity range

Humidity range fulfilling the conditions of the projected tests

 

Temperature Up and Down times

Temperature Up time and Temperature Down time needed for the cycle operations of the projected tests

 

Load Condition

Mass, Material and Calorific value (if any) of specimens

We are pleased to offer the Temperature/Humidity Cambers which will fulfill all requirements of above items.

 

Advanced Features of New Products 

■ Smaller Foot Prints and Easier Maintenance

  • The foot prints are 20% smaller1) compared with those of the conventional vertical/horizontal excitation changeover system to make installation easier.
  • With simplification of elevator mechanism, total system mass and risk of failures are reduced.

■ Easier Access, Improved Safety

  • Work to mount specimens is easier than ever by opening one side of the vibration generator.
  • Revolving light with buzzer is equipped for more safety

■ Expanded Feasibility

  • Different types of combined environmental tests are possible by one Temperature/Humidity chamber2) using the vibration generators of corresponding types arranged in line
  • By adding the optional Horizontal Base Floor to the system made oriented to vertical tests can be converted into conventional vertical/horizontal change over system.

1) In house comparison   2) One single set of Combined environmental chamber is usable at same time.

 

 

Standard Specifications

  • Volume size:W1000×D1000×H1000mm
  • Temperature range:-70℃~+180℃
  • Humidity range:20~98%RH 1)
  • Temperature up rate:1℃/min or faster(curve gradient) 2)
  • Temperature down rate:2℃/min or faster(curve gradient) 2)

1) There are ranges where humidity or temperature is controllable.  2) On request

 

 

Temperature/Humidity Chambers for Multi-axis excitation

Temperature/Humidity Chambers for Multi-axis excitation
  • Volume size:W1000×D1000×H1000mm
  • Temperature range:-70℃~+180℃
  • Humidity range:20~98%RH 1)
  • Temperature down rate:+20℃→-70℃ 40min(curve gradient) 2)
  • Temperature down rate:-70℃→+180℃ 40min(curve gradient) 2)

Achieved Specifications

1) There are ranges where humidity or temperature is controllable.
2) On request

 

Horizontal/Vertical excitation changeover Temperature/Humidity Chamber

Horizontal/Vertical excitation changeover Temperature/Humidity Chamber

  • Volume sizeW1000×D1000×H1000mm
  • Temperature range-40+180
  • Humidity range2098RH 1)
  • Temperature down rate+180→-40 100mincurve gradient 2)
  • Temperature down rate-40→+180 50mincurve gradient 2)

Achieved Specifications

  • A Single Temperature/Humidity chamber is used coupled with both of vertical and horizontal vibration table.

 

Large Temperature/Humidity Chamber

Achieved Specifications Large Temperature/Humidity Chamber

  • Volume sizeW1800×D1900×H1500mm
  • Temperature range-30+80
  • Humidity range6095RH 1)
  • Temperature down rate+45→-30 35mincurve gradient 2)
  • Temperature down rate-30→+80 25mincurve gradient) 2)

Achieved Specifications

  • The tests of large sized specimens as car seats, cut out bodies of cars, large home appliances are possible in large space

1) There are ranges where humidity or temperature is controllable.
2) On request

  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.

Similar Category