■ For malfunction detection of bearings
Piezoelectric Accelerometer(Pre-amplifier build-in type)
(1)VP-A51IW, VP-A4345I
■ For monitoring of velocity or displacement of 1 kHz or lower
Electrodynamic Velocity Pickup(Medium frequency type)
(2)VP-90 VC, VP-90 VD
■ For monitoring of displacement or velocity of 10Hz or lower
Electrodynamic Velocity Pickup(Low frequency type)
(3)VP-91 VC, VP-91 VD(Horizontal dedicated)
VP-92 VC, VP-92 VD(Vertical dedicated)
Common Specifications of Main Units
Classification |
Item |
Specification |
|
Signal Output |
Converted Output |
DC4-20mA、1 Output (Response time 3 sec*1) |
|
Monitor Output |
AC±5V FS±5%(for quick check)*3 1-5VDC FS±5%(option) |
||
Alarm Output |
Alarm Contact |
1 Step 1a Contact AC 125V、 DC 30V-1A (Resistive Load) |
|
Alarm Level Setting Extent |
0~100% of Full Scale Arbitrary Setting (in 1% Step)*2 |
||
Alarm Action |
Detecting the set Alarm level ,activates at the end of the Delay time (reset automatically) Initial Delay time setting 5sec (3~99sec: 1 sec Step) |
||
Indication |
Main Unit Panel Indicator |
Red 7 segment LED (4 Digit Indication) |
|
Vibration Amplitude |
5 Ranges for each selected function Blinks for over 120% of Full Scale |
||
Alarm Setting (%) |
1~100% for Full Scale*2 |
||
Pickup Sensitivity |
80~120% for Standard Sensitivity |
||
Ambient Environment |
Ambient Temperature |
-5~55℃ |
|
Ambient Humidity |
30~90%RH(No condensation) |
||
Others |
Supply Voltage |
AC100V±10% 50/60Hz±2Hz |
|
Installation |
On the Wall or DIN Rail (Din Rail contact section is demountable)On |
||
Terminal Board |
M3.5 screws on the Back Panel |
||
Outward Case Material |
Plastic |
||
Size・Mass |
W50×H80×D127mm Approx. 300g |
*1:Changeable by the customized software
*2: Setting of 0% cancels the alarm function.
*3:Usable for quick check of the waveforms
(1)Specifications of VM-90 DA (Applicable to Pre-amplifier build-in type Pickups)*6
(VP-A51 IW / VP-A 4345Ⅰ)
Measurement Mode |
Item |
Specification |
|
Acceleration*5 |
Measurement Range |
10, 20, 50, 100, 200(m/s2rms) |
|
Frequency Range |
10~4kHz±1dB |
||
Velocity*5 |
Measurement Range |
5, 10, 20, 50, 100(mm/s rms) |
|
Frequency Range |
10~1kHz+1dB、-2dB |
||
H Function*5 |
Measurement Range |
10, 20, 50, 100, 200(m/s2rms) |
|
Frequency Range |
DC~1kHz(Envelope detection of 2kHz~15kHz) |
||
H Function CF*5 |
Measurement Range |
5, 10, 20, 50, 100 |
|
Frequency Range |
DC~1kHz(for peak/rms of H Function) |
*5:Changeover of the measurement mode is possible by the switch located on the front panel.
*6:Designate the type of the main unit on placing order
(2)VM-90 DV Specifications (Using Medium Frequency Pickups)*6
(VP-90 VC / VP-90 VD)
Mode |
Item |
Specification |
|
Velocity*5 |
Measurement Range |
5,10,20,50,100(mm/s rms) |
|
Frequency Range |
10~1kHz+1dB |
||
Displacement*5 |
Measurement Range |
50,100,200,500,1000(μmp-p) |
|
Frequency Range |
10~500Hz±1dB |
*5:Changeover of the measurement mode is possible by the switch located on the front panel.
*6:Designate the type of the main unit on placing order
(3)VM-90 DV Specifications (Using Low Frequency Pickups)*6
(VP-91 VC / VP-91 VD / VP-92 VC / VP-92 VD)
Mode |
Item |
Specification |
|
Velocity*5 |
Measurement Range |
5,10,20,50,100(mm/s rms) |
|
Frequency Range |
5~500Hz+1dB |
||
Displacement*5 |
Measurement Range |
50,100,200,500,1000(μmp-p) |
|
Frequency Range |
5~500Hz±1dB |
*5:Changeover of the measurement mode is possible by the switch located on the front panel.
*6:Designate the type of the main unit on placing order
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.