Model |
VM-9201 series |
VM-9201 A series |
|||||||
Pickup |
Electrodynamic Velocity Pickup |
Piezoelectric Accelerometer |
|||||||
Frequency Range |
|
|
|||||||
Displacement Range |
20,30,50,100,150,200,300,500μmp-p Full scale selectable |
TBD |
|||||||
Velocity Range |
10,15,20,30,50mm/s Full scale selectable 1.0,1.5,2.0,3.0,5.0,10,20cm/s Full scale selectable |
TBD |
|||||||
Acceleration Range |
― |
10,15,20,30,50,100,150,200,300,500m/s2 Full scale selectable(1 Range) |
|||||||
Equipment failure |
Indication Lump |
Activate on fuse blown, power switch shut off, Primary / secondary power shut off LED orange lamp[FAT]turns on : on detecting abnormality for secondary side |
|||||||
Alarm Contact |
1a Contact(open for normal) |
||||||||
Alarm Reset |
|
||||||||
Pickup Cable Break Alarm |
Indication Lamp |
Activate when pickup cable is broken. LED green lamp[PU]turns off : detecting Broken pickup cable (lights on for normal) |
― |
||||||
Alarm Contact |
Standard : 1a (1b or 1c is available on request) |
||||||||
DC Output on Cable Break |
|
||||||||
Alarm Reset |
|
||||||||
Alarm |
Delay Timer |
Activates when the set levels are exceeded. |
|||||||
Alarm Step |
Upper 2 steps : alarm / trip 0 -15sec : selected by the slide switch located in the amplifier unit. 0 sec. for no designation |
||||||||
Setting Extent |
9.9 ~99.9% arbitrary setting by 0.1% step (99.9% setting for no alarm, indication lamp lights for over scale. Contacts activate) |
||||||||
Indication Lamp |
LED orange〔ALM〕 LED red〔TRP〕 |
||||||||
Alarm Contact |
|
||||||||
Contact Capacity |
AC250V 4A(Panasonic S relay) DC30V~3A |
||||||||
Alarm Reset |
|
||||||||
Detected Level Output (Isolated) |
|
||||||||
Pickup |
Depends on the pickup used AC±10mV /(mm/s)or AC±17.5mV(mm/s) Load 100kΩ or higher |
Depends on the pickup used AC±5mV /(m/s2) or load 100kΩ or higher |
|||||||
Waveform Output |
AC±5V or load 100kΩ higher |
||||||||
Panel Meter |
LED red 3 digit display,[9.9.9]display for over 120% of full scale |
||||||||
Ambient Temperature / Humidity |
0~+50℃, 20~95%RH, Max 35℃ in wet-bulb temperature (no condensation) |
||||||||
Power Supply |
Usable voltage : AC85~264V, 47~66Hz |
||||||||
Power Consumption |
1ch type : 30VA or less, 3ch type : 50VA or less, 6ch type : 90VA or less, 9ch type 140VA or less, 12ch type : 180VA or less for AC 100V power supply(depends on actual unit number of amplifiers and kind of power supply) |
||||||||
Painted Color |
Munsell 5Y7 / 1 , half matted |
*Every model of UM-9201 A series can be also used for Velocity, Displacement, H function measurements. Contact us for details.
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.