A quick introduction to the LeveLine water level and temperature logger.
The LeveLine collects water level data at user-defined intervals and stores the information in its internal memory. The logger can take up to an impressive 10 readings per second and the huge internal memory is capable of storing up to 500,000 readings. Made from titanium, the LeveLine is built for deployment in all kinds of water from fresh groundwater to salty marine waters.
Take a look at the full set of features:
It is constructed with harsh environments in mind and has an ultra rugged titanium body, as well as connectors that are highly resistant to corrosion. The Delrin nose cone reduces fouling of the pressure sensor, which extends the length of deployment, maintains data accuracy and extends the life of the LeveLine.
Aquaread’s LeveLine is available with both vented (gauge) and non-vented (absolute) Kevlar reinforced cables that allow for real-time monitoring. If you choose the non-vented version we also manufacture a barometric pressure monitor, LeveLine – BARO. This unit is to be placed out of the water, in the vicinity of the water level logger. Each baro logger provides compensation data for multiple water level loggers that are close by. You can even select the desired testing depth range to ensure the best resolution at your chosen monitoring site. You can hook the LeveLine directly to a telemetry device because it outputs in SDI-12 as standard but if you opt for a more hands on approach you can monitor in real time using your laptop or the GPS LeveLine meter.
The battery in each LeveLine can last for 10 years, which combined with the low maintenance requirements means that the LeveLine is ideal for deployment over a number of years. Combine the LeveLine with small ‘in-well’ telemetry system soon to be available and you have a powerful yet discrete monitoring system.
The LeveLine has multiple applications including: aquifer characterisation; watershed, drainage basin and recharge monitoring; harbor and tidal fluctuation monitoring; and industrial uses. The LeveLine water level logger provides highly accurate water level monitoring and can document baseline and changing water levels over time.
The LeveLine is Modbus (RS485) and SDI-12 compatible, so no adaptors are necessary and it allows direct connection to telemetry and SCADA systems. The external 6-30V power supply input is compatible with batteries and solar power. Our water level logging equipment comes with intuitive PC software suite that allows simple set up and data retrieval.
The LeveLine is the only water level logger to use the QuickDeploy Key or the GPS LeveLine Meter see how they can make your deployment simpler.
Connect the LeveLine logger to your PC to set up your logging scheme. Using the LeveLink software you are able to:
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Temperature ranges | Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Diameter | 22.2mm (0.875 in) | 22.2mm (0.875 in) | 22.2mm (0.875 in) | 22mm | 22mm |
Length | 186mm (7.32 in) | 186mm (7.32 in) | 87mm (3.43 in) | 260mm | 146mm |
Weight | 150g (5.3oz) | 160g (5.6oz) | 120g (4.2oz) | 250g | 210g |
Materials | Titanium body, Delrin nose cone | Stainless Steel body, Delrin nose cone | Stainless Steel body, Delrin nose cone | Titanium body, Delrin nose cone | Titanium body, Delrin nose cone |
Output options | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary |
Battery type & life | 3.6V lithium; up to 10 years (see note 1) | 3.6V lithium; up to 10 years (see note 1) | N/A | 3.6V lithium; up to 10 years (see note 1) | N/A |
External power | 6 – 30 VDC | 6 – 30 VDC | 6 – 30 VDC | 6 – 24 VDC | 6 – 24 VDC |
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Size | 8.0 MB | 2.0 MB | N/A | 8.0 MB | N/A |
Data records | 500,000 | 150,000 | N/A | 500,000 | N/A |
Log types | Linear, Event & User-Selectable Schedule with Future Start, Future Stop, Deploy Start and Real Time View |
Linear, Event & User-Selectable Schedule with Future Start, Future Stop, Deploy Start and Real Time View |
N/A | Linear, Event & User-Selectable Schedule with Future Start, Future Stop, Deploy Start and Real Time View |
N/A |
Fastest logging rate & Modbus rate | 10 per second | 1 per minute (logging) 5 per second (Modbus) |
10 per second (Modbus Rate) | 1 per second | 1 per second |
Fastest SDI-12 output rate | 1 per second | 1 per second | 1 per second | 1 per second | 1 per second |
Real-time clock | Accurate to 1 second/24-hr period (± 6 minutes/year) | Accurate to 1 second/24-hr period (± 6 minutes/year) | N/A | Accurate to 1 second/24-hr period (± 6 minutes/year) | N/A |
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Type / Material | Piezoresistive; ceramic | Piezoresistive; ceramic | Piezoresistive; ceramic | Piezoresistive; ceramic | Piezoresistive; ceramic |
Range (Absolute) | 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) | 0 to 16.7 psi; 0 to 1.15 bar | 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) |
Range (Gauge) | 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) | N/A | N/A | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) |
Maximum pressure | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range |
Accuracy (FS) (see note 3) | ±0.05% FS | ±0.1% FS | ±0.05% FS | ±0.05% FS | ±0.05% FS |
Accuracy (FS) (See note 2) | ±0.1% FS | ±0.2% FS | ±0.1% FS | ±0.1% FS | ±0.1% FS |
Resolution | 0.005% FS or 1mm whichever is greater | 0.1mb | 0.005% FS or 1mm whichever is greater | 0.002% FS or 1mm whichever is greater | 0.002% FS or 1mm whichever is greater |
Units of measure | Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m | Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O | Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m | Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink | Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink |
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Range | N/A | N/A | N/A | 0 – 200mS/cm (0 – 200,000µS/cm) | 0 – 200mS/cm (0 – 200,000µS/cm) |
Resolution | N/A | N/A | N/A | 1µS | 1µS |
Accuracy | N/A | N/A | N/A | ± 1% reading or ±1µS whichever is greater (see note 5) | ± 1% reading or ±1µS whichever is greater (see note 5) |
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Range | N/A | N/A | N/A | 0 – 70 PSU / 0 – 70 ppt (g/Kg) | 0 – 70 PSU / 0 – 70 ppt (g/Kg) |
Resolution | N/A | N/A | N/A | 0.01PSU / 0.01 ppt | 0.01PSU / 0.01 ppt |
Accuracy | N/A | N/A | N/A | ±1% reading or ± 0.1 unit if greater | ±1% reading or ± 0.1 unit if greater |
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Accuracy Resolution | ±0.1° C 0.01° C |
±0.1° C 0.01° C |
±0.1° C 0.01° C |
±0.1° C; 0.01° C | ±0.1° C; 0.01° C |
Units of measure | Celsius | Celsius | Celsius | Celsius (fahrenheit available in LeveLink) | Celsius (fahrenheit available in LeveLink) |
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Standard | N/A | N/A | N/A | 2 years | 2 years |
Extended | N/A | N/A | N/A | Options Available | Options Available |
Notes: 1) Dependent on logging rate. 2) Across factory-calibrated pressure range at a constant temperature. 3) Across factory-calibrated pressure and temperature ranges. 4) Readings calculated from EC and temperature values. 5) At the calibration point at 25°C