Red Star Vietnam Co., Ltd.
Icons giỏ hàng Cart 0
Total : đ

ST-50G Autoclave

State: Out of stock
Microprocessor control with reliable safety functions guarantees optimum sterilization temperature.
Top loading, vertical chamber design maximizes efficient space application. Microprocessor control with enhanced program functions enables precise and convenient operations.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

● Operational Features

 

Microprocessor controller and temperature calibration function allows for high precision temperature control. 

 

- Sterilization temperature at 110 to 123°C
- Melting* temperature at 60 to 100°C (* liquefaction of coagulated agar media.)

 

Automatic sterilization system for unattended operation. Sterilization process runs automatically in sequence as listed below.
- Heating > Check Safe > Sterilization > Sterilization Safe > Exhausting > End.

 

Convenient operation modes for various uses. 
- Standard modes and program modes are listed in detail as above tables.

 

Conveniently monitored by an independent control display, sterilization process display, and pressure gauge.
- VFD for visualization of temp, pressure (optional), timer, warning alert checks.
- LED lamps for sterilization process check.
- Easy pressure check with the standard gauge attached to the front.

Temperature calibration function.

 

● Convenient Operation Modes

 

Standard Modes

 

Modes Temp. (°C) Time (min)
Decontamination 121 35
Solids Sterilization 121 20
Liquids Sterilization 121 15
Melting 100 30

 

Program Modes

 

Modes Temp. (°C) Time (min)
Sterilization 1 110 to 123 1 to 999
Sterilization 2 110 to 123 1 to 999
Liquid Sterilization 110 to 123 1 to 999
Melting 60 to 100 1 to 999

 

● Safety Features

 

Mechanical Safety Devices: 
- Over current protection:
Two separate fuses for protection against overcurrent.
- Over temperature protection:
If the temperature of inner chamber exceeds the temperature limit, over temperature protection device inactivates the heater.
- Over Pressure Protection:
If the pressure of inner chamber exceeds the pressure limit, the automatic safety valve will release the pressure out from the chamber. In other emergency situations, the pressure can be controlled manually by opening the manual safety valve.

 

Safety Warning Systems
- Over Temperature Warning:
If the temperature exceeds 125°C for more than 10 seconds, the unit will stop with visual and audible alarms.

 

- Low Temperature Warning:
If the temperature stays below set temperature value for more than 5 seconds, visual and audible alarms will warn for caution.

 

- Low Heat Warning:
If the temperature does not reach the sterilization or melting temperature during a certain periods, the unit will stop with visual and audible alarms.

 

- Sterilization Fail Warning:
If the operation is unexpectedly stopped during sterilization process, visual and audible alarms will warn for noticing incompletion.

 

- Low Water Level Warning:
If the water level goes down below a certain point during sterilization or melting process, the unit will stop with visual and audible alarms.

 

● Constructional Features

 

Vertical type autoclaves which allow for top loading are suitable for high volume sterilization. 
- Baskets are stackable two high or even more levels, which secure inside the chamber space requirements.
* Refer to the back cover for the information of basket and flask capacity

 

Slide opening door with plastic cover of low thermal conductivity prevents burns from the contact.

 

Low-maintenance.
- The chamber is constructed of stainless steel which is superiorly resistant to corrosion.
- Easy to replace silicone gasket.

Convenient documentation with the optional data recorder.
- Dot type recorder(6 point) allows for precise documentation.

Model

ST-50G

Control

Microprocessor PID Control

Chamber Volume (L / cu ft)

50 / 1.8 65

Temperature 1)

Sterilization Temp. (/)

110 to 123 / 198 to 221.4

Melting Temp. (/)

60 to 100 / 108 to 180

Safety

Over Temperature Protector / Pressure Safety Valve / Over Current Protector

Warning Alert (Over Temp. / Low Temp. / Low Heat / Sterilization Fail / Low Water Level)

Timer

0 to 999 min

Programs

Standard modes (Decontamination, Solids Sterilization, Liquids Sterilization, Melting)

Program modes (Sterilization 1, Sterilization 2, Liquid Sterilization, Melting)

Dimension

No. of Baskets (Standard / Max.)

2 / 2

Load per Baskets (Kg / lbs)

10 / 22.0

Basket (ØxH) (mm / inch)

380x180 / 14.9x7.1

Interior (WxH) (mm / inch)

400x458 / 15.7x18.0

Exterior 2) (W×D×H) (mm / inch)

624x672x870 / 24.6x26.5x34.2

Net Weight (Kg / lbs)

94.5 / 208.3

Electrical Requirements (230V, 50 / 60 Hz)

14.3A

 

1) Technical data according to EN 554 / BS EN 285:1997.
2) Exterior size is measured without the size of exhaust tank.
* Permissible environmental conditions: temperature (5-40℃) and relative humidity (10-80%).
* Above specifications can be changed without prior notice.

 

 

Flask Loading Capacity

 

At Max. loading capacity, partially without baskets.

 

Description

Capacity

ST-50G (ea x floor)

Erlenmeyer Flasks
(O.D.xH, mm)

250 mL (82 x 132)

14x3

500 mL (101 x 176)

8x2

1000 mL (129 x 216)

5x2

2000 mL (160 x 268)

3x1

Media Bottles
(O.D.xH, mm)

250 mL (70 x 143)

20x3

500 mL (86 x 181)

14x2

1000 mL (101 x 230)

8x1

2000 mL (136 x 265)

5x1