● Comes with all functions and equipment features of the BZ25
● Autonomous long-term recording of carbon dioxide concentration, room temperature and humidity
● Storage for 50,000 measured values
● Freely definable saving interval from 1 second to 12 hours
● USB interface for measuring data transfer
● For table installation and mobile application
● PC analysis software
This CO₂ air quality data logger is the ideal combination measuring device for architects, experts and every heating, ventilation and air conditioning engineer.
The BZ30 provides you with all functions and equipment features of the BZ25 and is further equipped with a large data memory for 50,000 measured values for the long-term recording of carbon dioxide concentrations, air temperature and humidity values in freely definable measuring intervals from 1 second to 12 hours.
The recorded data can be conveniently transferred to the connected PC via a fast USB connection and there analysed and logged using the analysis software included in the scope of delivery.
Owing to the integrated NiMH battery, the BZ30 is also suited for mobile application in addition to the stationary table installation.
The simultaneous recording of humidity and temperature values plus CO₂ concentrations offers property managers or landlords optimal possibilities to monitor the ventilation habits.
Master data |
|
Article number |
3.510.205.015 |
Air temperature |
|
Measuring principle |
NTC |
Measuring range [°C] |
-5 - 50 |
Accuracy [°C] |
± 1 |
Display resolution [°C] |
0,1 |
Relative humidity |
|
Measuring principle |
|
Measuring range [% RH] |
0,1 - 99,9 |
Accuracy [% RH] |
0,1 (max. ±5) |
Display resolution [% RH] |
0,1 |
Air pressure |
|
Measuring principle |
— |
Measuring range [hPa] |
— |
Accuracy [hPa] |
— |
Display resolution [hPa] |
— |
CO₂ concentration |
|
Measuring principle |
NDIR |
Measuring range [ppm] |
0 - 9.999 |
Accuracy |
±75 ppm / ±5 % |
Display resolution [ppm] |
1 |
Long-term stability [ppm/a] |
— |
Voltage input |
|
Min. measuring range [V] |
— |
Max. measuring range [V] |
— |
Accuracy [µV] |
— |
Accuracy [%] of the measured value |
— |
Resolution |
— |
Voltage measurement |
|
Min. measuring range [mA] in two-wire operation |
— |
Max. measuring range [mA] in two-wire operation |
— |
Min. measuring range [mA] in three-wire operation |
— |
Max. measuring range [mA] in three-wire operation |
— |
Accuracy [µA] |
— |
Accuracy [%] of the measured value |
— |
Resolution [µA] |
— |
Output load [Ω] |
— |
Thermal element K |
|
Min. measuring range [°C] |
— |
Max. measuring range [°C] |
— |
Accuracy between -200 °C ... 0 °C [°C] |
— |
Accuracy between -200 °C ... 0 °C [%] of the measured value |
— |
Accuracy between 0 °C ... 1,200 °C [°C] |
— |
Accuracy between 0 °C ... 1,200 °C [%] of the measured value |
— |
Resolution [°C] |
— |
Thermal element J |
|
Min. measuring range [°C] |
— |
Max. measuring range [°C] |
— |
Accuracy between -200 °C ... 0 °C [°C] |
— |
Accuracy between -200 °C ... 0 °C [%] of the measured value |
— |
Accuracy between 0 °C ... 1,200 °C [°C] |
— |
Accuracy between 0 °C ... 1,200 °C [%] of the measured value |
— |
Resolution [°C] |
— |
Thermal element S |
|
Min. measuring range [°C] |
— |
Max. measuring range [°C] |
— |
Accuracy between -50 °C ... 0 °C [°C] |
— |
Accuracy between -50 °C ... 0 °C [%] of the measured value |
— |
Accuracy between 0 °C ... 1,700 °C [°C] |
— |
Accuracy between 0 °C ... 1,700 °C [%] of the measured value |
— |
Resolution [°C] |
— |
Pt100 |
|
Min. measuring range [°C] |
— |
Max. measuring range [°C] |
— |
Accuracy [°C] |
— |
Accuracy [%] of the measured value |
— |
Resolution [°C] |
— |
Interfaces |
|
LAN |
— |
Plug socket |
— |
BNC |
— |
RS-485 |
— |
10-pin terminal |
— |
USB |
√ |
Power supply |
|
Internal (battery) |
NiMH battery or 230 V power supply |
External (USB) |
— |
External via LAN (PoE model) |
— |
Terminals for external power supply to supply the sensor |
— |
Display |
|
Dimensions [mm] |
— |
LCD |
√ |
Memory organization |
|
Sensing interval |
> 1 s |
Saving interval |
> 1 s |
Memory |
50,000 measured values |
Data logging |
— |
Available measurement channels |
— |
Available channel groups |
— |
Housing design |
|
Plastic |
√ |
Weight (packing excluded) |
|
Weight [kg] |
0,074 |
Dimensions (packing excluded) |
|
Length [mm] |
110 |
Width [mm] |
105 |
Height [mm] |
61 |
STANDARD SCOPE OF DELIVERY |
||
Battery(-ies) |
||
|
Option |
√ |
USB connection cable |
||
|
Option |
√ |
CD-Rom with Smartgraph PC software and operating manual |
||
|
Option |
√ |
ASCERTAINABLE MEASURED VALUES AND FUNCTIONS |
|
Internal sensors |
|
Air temperature [°C] |
√ |
Air temperature [°F] |
√ |
Relative humidity [%] |
√ |
Absolute humidity [g/m³] |
— |
Dew point temperature [°C] |
— |
Dew point temperature [°F] |
— |
Relative air pressure [hPa] |
— |
Absolute air pressure [hPa] |
— |
CO₂ -concentration [ppm] |
√ |
External sensors |
|
CO₂ -concentration [ppm] |
— |
Surface temperature [°C] |
— |
Surface temperature [°F] |
— |
Material temperature [°C] |
— |
Material temperature [°F] |
— |
Air temperature [°C] |
— |
Air temperature [°F] |
— |
Wood moisture [digits] |
— |
Building moisture [digits] |
— |
Relative humidity [%] |
— |
Absolute humidity [g/m³] |
— |
Dew point temperature [°C] |
— |
Dew point temperature [°F] |
— |
Battery voltage [mV, V] |
— |
Voltage [mV, V] |
— |
Current [mA, A] |
— |
Absolute air pressure [hPa, Pa] |
— |
Relative air pressure [hPa, Pa] |
— |
Differential pressure [Pa] |
— |
Flow rate [m/s] |
— |
Mixing ratio [g/kg dry air] |
— |
Particle concentration [0.1 µm] |
— |
Particle concentration [0.2 µm] |
— |
Particle concentration [0.3 µm] |
— |
Particle concentration [0.5 µm] |
— |
Particle concentration [1 µm] |
— |
Particle concentration [5 |
— |
Particle concentration [10 |
— |
Particle concentration [x µm] |
— |
Particle concentration [y µm] |
— |
Particle concentration [z µm] |
— |
Unknown |
— |
Inactive |
— |
Cooling limit temperature [°C] |
— |
Cooling limit temperature [°F] |
— |
Global radiation [W/m²] |
— |
Daylight |
— |
Amount of precipitation [l/m²] |
— |
Wind speed [m/s] |
— |
Wind direction |
— |
Ground dampness |
— |
Leaf wetness |
— |