EMIA-V2 series Carbon/Sulfur Combustion Analyzer

State: Out of stock
The EMIA-V2 series measures carbon and sulfur extracted during combustion in a programmable High Frequency furnace without conversion. Combustion control is achieved through the use of the high-frequency induction furnace method. Appropriate heat-control in accordance with the analysis objective enables high-precision analysis for all types of samples.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

The EMIA-V2 series measures carbon and sulfur extracted during combustion in a programmable High Frequency furnace without conversion. Combustion control is achieved through the use of the high-frequency induction furnace method. Appropriate heat-control in accordance with the analysis objective enables high-precision analysis for all types of samples. A variety of models allow you to select the furnace system that is best suited to your target samples and application.

 

  • EMIA-920V2 C/S analyzer: High performance analyzers with outstanding accuracy of less than 0.3ppm
  • EMIA-320V C/S analyzer: Standard performance analyzers for wide range of applications.

 

 

Features:

 

  • "Auto cleaner" mechanism reduced maintenance works 
    (Standard for 920V, Option for 320V2)

 

  • The Dust filter heating mechanism provides stable analysis with extremely low gas absorption 
    (920V2 only)

 

  • Real-time simultaneous detection of CO/CO2/SO2 without an oxidizing (COCO2) or SO3 trapping reagents.

 

  • Wide variety of self diagnostics

 

  • Programmed temperature curve for optimizing combustion.

 

  • Choose from standard or wide range models to suit your application requirements.

EMIA-920V2 series:

 

EMIA-920V2 Simultaneous carbon/sulfur analysis 
EMIA-921V2 Carbon analysis
EMIA-922V2 Sulfur analysis
Principle NDIR/ Non Dispersive Infrared Gas Anaryzer
High-frequency furnace method in oxygen flow
Range arbon: 0-6,0%, Sulfur: 0-1,0%
Up to 100% wt is possible by decreasing the sample weight.
Accuracy

Carbon: 
Concentration less than 20 ppm >>> σn-1≦0.3 ppm
Concentration higher than 20 ppm >>> σn-1≦1 ppm or RSD ≦0.5%

 

Sulfur:
Concentration less than 20 ppm >>> σn-1≦0.3 ppm
Concentration higher than 20 ppm >>> σn-1≦1 ppm or RSD ≦0.75%

Sample weight 1,0g standard
Sensitivit 0,01ppm 
Analysis time Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples
Calibration One-point or multi-point calibration using standard sample 
Combustion furnace method/furnace structure High-frequency induction furnace method with combustion control function (patent pending)
Anode output: 2300W
Frequency: 20MHz 
Plate current: Settable up to 500mA  
Automatic control possible (10 slopes maximum) 
Constant dust filter heating function 
Operation gas Oxygen purity: More than 99.5%
Dry air or nitrogen: Supply pressure 0.35MPa
Functions Interrupt analysis
Self diagnosis
Data storage(Measurement results)
Traceability of calibration curve and measurement conditions
Statistic calculation
Maintenance navigator
Automatic cleaning mechanism Built-in as standard
Oxygen gas purifying unit Built-in as standard
Power Main unit: AC200/220/240V  5kVA  50/60Hz
PC: AC100V, 120/200/220/240V  0.5kVA  50/60Hz
Dimensions 560(W)×927(D)×950(H)mm Approx.170 kg

 

 

EMIA-320V2 series:

 

EMIA-320V2 Simultaneous carbon/sulfur analysis
EMIA-321V2 Carbon analysis
EMIA-322V2 Sulfur analysis
Principle NDIR/ Non Dispersive Infrared Gas Anaryzer
High-frequency furnace method in oxygen flow
Range Carbon: 0-6.0%, Sulfur: 0-1.0%
Up to 100% wt is possible by decreasing the sample weight.
Accuracy Carbon: σn-1≦2 ppm or RSD≦1.0%
Sulfur: σn-1≦2 ppm or RSD≦1.5%
Sample weight 1,0g standard
Sensitivity  0,1ppm 
Analysis time Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples
Calibration One-point or multi-point calibration using standard sample 
Combustion furnace method/furnace structure High-frequency induction furnace method with combustion control function (patent pending)
Anode output: 2300W
Frequency: 20MHz 
Plate current: Settable up to 500mA  
Automatic control possible (10 steps maximum) 
Operation gas Oxygen purity: More than 99.5%
Dry air or nitrogen: Supply pressure 0.35MPa
Functions Interrupt analysis
Self diagnosis
Data storage(Measurement results)
Memory of calibration curve and measurement conditions
Statistic calculation
Automatic cleaning mechanism Option
Oxygen gas purifying unit Option
Power Main unit: AC200/220/240V  5kVA  50/60Hz
PC: AC100V, 120/200/220/240V  0,5kVA  50/60Hz
Dimensions 560(W)×885(D)×820(H)mm Approx.170 kg

 

 

Schematics:

 

EMIA-V2 series Carbon/Sulfur Combustion Analyze