● Silent system design
The water cooling system produces neither the intake nor exhaust sounds that an air cooling system emits.
● Record of significant accomplishments]
IMV has been developing the water cooling system ahead of other domestic manufacturers.
|
System Model |
K030/SA4MM |
K049/SA6MM |
K062/SA8MM |
K080/SA14HM |
K100/SA18HM |
K125/SA22HM |
K160/SA26HM |
K200/SA32HM |
|
|
Freq. Range(Hz) |
0~ |
0~ |
0~ |
0~ |
0~ |
0~ |
0~ |
0~ |
|
System |
Rated |
SINE(kN) |
30.8 |
49.0 |
61.7 |
80 |
100 |
125 |
160 |
200 |
RANDOM |
21.5 |
49.0 |
61.7 |
80 |
100 |
125 |
160 |
200 |
||
SHOCK(kN) |
61.6 |
98 |
123.4 |
160 |
200 |
250 |
320 |
400 |
||
Max. |
SINE (m/s2) |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
800 |
1000 |
|
RANDOM |
557 |
700 |
700 |
700 |
700 |
700 |
700 |
700 |
||
SHOCK(m/s2) |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1600 |
2000 |
||
Max. |
SINE(m/s) |
1.8*5) |
2.0*5) |
2.0*5) |
2.0*5) |
2.0*5) |
2.0*5) |
2.0*5) |
2.0*5) |
|
SHOCK(m/s) |
1.8 |
2.0 |
2.0 |
2.0 |
2.0 |
2.0 |
2.4 |
2.4 |
||
Max. |
SINE(mmp-p) |
51 |
51 |
51 |
51 |
51 |
51 |
76.2 |
76.2 |
|
MAX. TRAVEL |
58 |
60 |
60 |
59 |
62 |
62 |
86 |
86 |
||
Max. Load.(kg) |
500 |
1000 |
1000 |
1000 |
2000 |
2000 |
2000 |
2000 |
||
Power Requirements |
49 |
76 |
87 |
100 |
150 |
170 |
270 |
300 |
||
Vibration |
Model |
K030 |
K060 |
K060 |
K080 |
K125 |
K125 |
K200 |
K200 |
|
Armature Mass(Kg) |
27 |
40 |
40 |
60 |
70 |
70 |
200 |
200 |
||
Armature Diameter |
320 |
400 |
400 |
446 |
560 |
560 |
650 |
650 |
||
Allowable eccentric moment |
980 |
980 |
980 |
1550 |
2450 |
2450 |
4900 |
4900 |
||
Dimensions(mm) |
1100x |
1380x |
1380x |
1595x |
1776x |
1776x |
2465x |
2465x |
||
Mass(kg) |
3000 |
3700 |
3700 |
5000 |
7000 |
7000 |
16000 |
16000 |
||
Power |
Model |
SA4MM-K30 |
SA6MM-K60 |
SA8MM-K60 |
SA14HM-K80 |
SA18HM-K125 |
SA22HM-K125 |
SA26HM-K200 |
SA32HM-K200 |
|
Max. Output(kVA) |
33 |
43 |
60 |
100 |
98 |
124 |
256 |
320 |
||
Dimensions(mm) |
580x |
1160x |
1160x |
1740x |
1740x |
2320x |
2900x |
3480x |
||
Mass(kg) |
950 |
1300 |
1350 |
2250 |
2400 |
3200 |
4000 |
4800 |
||
Controller |
Vibration Controller |
See Vibration Controller K2 |
||||||||
Cooling |
Cooling Method |
Cooling Method Shaker:Water cooling/Power Amplifier:Air Cooling |
||||||||
Primary Cooling |
195 |
260 |
260 |
390 |
390 |
390 |
520 |
520 |
||
Heat |
Dimensions(mm) |
580x |
580x |
580x |
580x |
580x |
580x |
950x |
950x |
|
Mass(kg) |
400 |
400 |
400 |
400 |
400 |
400 |
600 |
600 |
*1) Power supply required is 3-phase 200/220/240/380/400/415/440V,50/60Hz. Voltage Down Transformer (Step-down transformer) is required for other voltage.
*2) Rated force of RANDOM follow the ISO5344 standard. Please contact us for further information on RANDOM force conditions of each system.
*3) Each value of specification indicates maximum power of the system. In the case of a long hours of test, it needs to be operated less than 70% of maximum power.
(The continuous use could be the cause of a premature failure.)
*4) In the case of RANDOM durability test, please set the test definition of the peak value of acceleration waveform to be operated less than 1400 m/s2.
*5) If the tests (SWEEP or SPOT) need high velocity, the maximum velocity value should be reduced to 1.4m/s.
In the case of continuous SINE test, at move than 1.4m/s, it may need optional cooling system, so please consult with us.
*6) Frequency range values vary according to sensor and signal generator.
*7) Mass and size can change in CE-support system.