Constructional Features
● Air-tight door closure with double sealed packings.
- Heat-resistant silicone double packing completely blocks high heat leakage from the inner chamber.
(only for LBV Models)
- Non-conducting ceramic and heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.(only for LTV Models)
- Two-point door latch also enhances tightness to door closure.
● Energy efficiency is achieved thanks to optimization of the insulation system.
- Even if the unit is operating at max. temperature, the surface of the unit doesn’t allow high temperatures of over 51℃. (DIN EN 563)
● Reliable design and production of door is guaranteed.
- Evaluates the results after opening the door by 90 degrees and applying 50kg load to the point of 30cm from hinges.
● Corrosion resistance stainless steel inner chamber.
● Space efficient and easy loading chamber design.
- Included two shelves for loading of large amounts of samples.
- Heavy load shelving, rated for 40kg are also available. (optional)
Safety Features
● Over-current & Current Leakage Protection. (ELCB, Earth Leakage Circuit Breaker)
● Independent Safety Fuse.
- Important parts such as controller and heaters are highly secured from short circuit. Especially each heater has an individual fuse to completely break a short circuit.
● Reversed-phase Protection.
- Electrical connection error indicator helps user to rapidly fix the connection
● Over-current Protection of Motor.
- Automatic Shut-off in situations where there is over-current to the Motor.
● Door Open Warning.
- Heater & Fan stop when the door is the open state.
● Electric wiring panel access warning.
- Automatic stop if the cover of electric wiring panel is opened.
Operating Features
● Suitable for specific use such as heat treatment and drying process.
● Colorful interactive touch type LCD controller.
● Set point temperature and present temperature areclearly shown together on display.
● Sufficient programmable control support.
● Operating progress can be shown in graph mode for better data understanding.
● Automatic start/stop can be programmed for unattended operations.
● User selectable operation mode after power interruption -ether Automatic run or Manual run.
● Display indicates abnormal temperature changes or power failures.
● Three different language support. (English / Chinese / Korean)
● Temperature and other operating parameters can be recorded using a six channel digital recorder.(optional)
Software
● RS-485 communication port(optional) enables connection up to maximum 32 units. Simultaneous monitoring and operating of multiple units is an available feature.
● Program patterns are simple to set with the use of our software.
● Easy to check status of real-time operations.
● Graph data supports easy understanding.
● Storage and documentation of programs.
● Data with saving capabilities in excel and text format.
● Storage of program information, backup of value settings, recovery, and temperature values.
● RS-232 communication port as standard offer.
Model |
LBV-012 |
LBV-025 |
LBV-040 |
LBV-070 |
LBV-100 |
|
Chamber Volume (L / cu ft) |
125 / 4.4 |
253 / 8.9 |
420 / 14.8 |
720 / 25.4 |
1000 / 35.3 |
|
Controller |
Programmable, Touch screen type controller (3.5" Color monitor) |
|||||
Temperature |
intake/damper |
Amb.+45 to 250 / Amb. +113 to 482 |
||||
intake/damper |
Max. 80 / Max. 176 |
Max. 80 / Max. 176 |
Max. 120 / Maz. 248 |
Max. 80 / Max. 176 |
Max. 140 / Max. 284 |
|
Temperature Fluctuation 1) 2) |
0.3 / 0.54 |
0.3 / 0.54 |
0.3 / 0.54 |
0.3 / 0.54 |
0.3 / 0.54 |
|
Temperature |
at 100℃ |
0.4 / 0.72 |
0.4 / 0.72 |
1.3 / 2.34 |
0.5 / 0.90 |
0.5 / 0.90 |
at 150℃ |
0.7 / 1.26 |
0.7 / 1.26 |
2.3 / 4.14 |
0.7 / 1.26 |
0.8 / 1.44 |
|
at 200℃ |
1.1 / 1.98 |
1.1 / 1.98 |
3.2 / 5.76 |
1.1 / 1.98 |
1.2 / 2.16 |
|
at 250℃ |
1.7 / 3.06 |
1.7 / 3.06 |
4.1 / 7.38 |
1.5 / 2.70 |
1.7 / 3.06 |
|
Heating Time 2) (min.) from Amb. to 250℃ |
51 |
51 |
51 |
55 |
60 |
|
Recovery time 2) |
at 100℃ |
10.5 |
10.5 |
8 |
6.5 |
8 |
at 150℃ |
8 |
8 |
9 |
8 |
9.5 |
|
at 200℃ |
4.5 |
4.5 |
8.5 |
7 |
8.5 |
|
at 250℃ |
5 |
5 |
9.5 |
5.5 |
9.5 |
|
Air Change rate (approx, x/h) |
213 |
266 |
173 |
233 |
193 |
|
Air Circulation (approx, x/h) |
374 |
590 |
294 |
348 |
220 |
|
Exhaust air volume flow (approx, L/min) |
380 |
1240 |
1400 |
1910 |
1560 |
|
Air flow velocity (m/s) |
0.2 to 0.6 |
0.2 to 0.6 |
0.2 to 0.6 |
0.2 to 0.6 |
0.2 to 0.6 |
|
Dimension |
Interior (mm / inch) |
500×500×500 |
600×650×650 |
750×700×800 |
900×800×1000 |
1000×910×1100 |
Exterior (mm / inch) |
1100×745×1362 |
1200×995×1559 |
1350×1045×1712 |
1500×1145×1912 |
1600×1255×2012 |
|
Net Weight |
170 / 374.8 |
260 / 573.2 |
320 / 705.5 |
390 / 859.8 |
440 / 970 |
|
Interface Port |
Basically RS-232C [RS-485(Maximum 32 Units Control)-optional] |
|||||
Electrical Requirements (230V, 60Hz) |
1ph / 14A |
1ph / 21.3A |
||||
Cat. No. |
AAHK1011K |
AAHK1021K |
- |
- |
- |
|
Electrical Requirements (230V, 50Hz) |
1ph / 14A |
1ph / 21.3A |
3ph / 16.2A |
3ph / 20.7A |
3ph / 24.6A |
|
Cat. No. |
AAHK1012K |
AAHK1022K |
AAHK10312K |
AAHK10412K |
AAHK10512K |
|
Electrical Requirements (380V, 50Hz) |
3ph / 9.4A |
3ph / 12A |
3ph / 14.2A |
|||
Cat. No. |
- |
- |
AAHK1038K |
AAHK1048K |
AAHK1058K
|