Red Star Vietnam Co., Ltd.
Icons giỏ hàng Cart 0
Total : đ

Heating chmaber JEIO TECH LTV-040 (LTV type)

State: Out of stock
Temperature values of all chambers are measured according to DIN 12880 and IEC 60068-3-5.
Warranty: 12 months


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

Reliable International Standard

Designed and tested in accordance with the international standards.
Temperature values of all chambers are measured according to IEC 60068-3-5 and DIN 12880.

Increase in reliability of accurate temperature implementation and test results. (27 point measurement data)

 

Uniform Air Circulation

An unrivalled designed air circulation system boostsa uniform temperature distribution.

- Horizontal forced convection increases temperature uniformity by flowing heated air throughout the whole chamber.
- Air intake and exhaust damper rapidly cools-down and ventilates chamber.
- Various applications are available for higher air exchange.
- Freely control of air volume by adjusting the air flap position with damper handle based on individual application needs.
- Safe damper guard protect users from overheated damper.

 

LBV series

Amb.+45 to 250℃ / Amb. +113℉ to 482℉
Horizontal Airflow

LTV series

Amb.+45 to 350℃ / Amb. +113℉ to 662℉

Horizontal Airflow
 

 

 

Constructional Features

 

● Air-tight door closure with double sealed packings.
- Heat-resistant silicone double packing completely blocks high heat leakage from the inner chamber. (only for LBV Models)
- Non-conducting ceramic and heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.(only for LTV Models)
- Two-point door latch also enhances tightness to door closure.

● Energy efficiency is achieved thanks to optimization of the insulation system.
- Even if the unit is operating at max. temperature, the surface of the unit doesn’t allow high temperatures of over 51℃. (DIN EN 563) 

● Reliable design and production of door is guaranteed.
- Evaluates the results after opening the door by 90 degrees and applying 50kg load to the point of 30cm from hinges.

● Corrosion resistance stainless steel inner chamber.

● Space efficient and easy loading chamber design.
- Included two shelves for loading of large amounts of samples.
- Heavy load shelving, rated for 40kg are also available. (optional)

 

Safety Features

 

● Over-current & Current Leakage Protection. (ELCB, Earth Leakage Circuit Breaker) Independent Safety Fuse.
- Important parts such as controller and heaters are highly secured from short circuit. Especially each heater has an individual fuse to completely break a short circuit.

● Reversed-phase Protection.
- Electrical connection error indicator helps user to rapidly fix the connection

● Over-current Protection of Motor.
- Automatic Shut-off in situations where there is over-current to the Motor.

● Door Open Warning.
- Heater & Fan stop when the door is the open state.

● Electric wiring panel access warning.
- Automatic stop if the cover of electric wiring panel is opened.

 

 

Operating Features

 

Suitable for specific use such as heat treatment and drying process.
Colorful interactive touch type LCD controller.
Set point temperature and present temperature areclearly shown together on display.
Sufficient programmable control support.
Operating progress can be shown in graph mode for better data understanding.
Automatic start/stop can be programmed for unattended operations.
User selectable operation mode after power interruption -ether Automatic run or Manual run.
Display indicates abnormal temperature changes or power failures.
Three different language support. (English / Chinese / Korean)
Temperature and other operating parameters can be recorded using a six channel digital recorder.(optional)
Programming operation.

 

 

Description

No.

Programmable Pattern Capacity

100

Pattern Repeat Time

999

Part repeat time

255

Max. Segments per a Pattern

100

Available Max. Segments*

6000

Programmable Process Time per a Segment

0 to 99 hr 59 min

 

* Even though the max. segments per pattern are 100, the total available segments are up to 6000 not 10000, therefore arrangementof the number of segment and patterns will need to be done properly.

 

 

Software

 

● RS-485 communication port(optional) enables connection up to maximum 32 units. Simultaneous monitoring and operating of multiple units is an available feature.

● Program patterns are simple to set with the use of our software.
● Easy to check status of real-time operations.
● Graph data supports easy understanding.

● Storage and documentation of programs.
● Data with saving capabilities in excel and text format.
● Storage of program information, backup of value settings, recovery, and temperature values.
● RS-232 communication port as standard offer.

Model

LBV-012

LBV-025

LBV-040

LBV-070

LBV-100

Chamber Volume (L / cu ft)

125 / 4.4

253 / 8.9

420 / 14.8

720 / 25.4

1000 / 35.3

Controller

Programmable, Touch screen type controller (3.5" Color monitor)

Temperature
Range (
/ )

intake/damper
100% close

Amb.+45 to 250 / Amb. +113 to 482

intake/damper
100% open

Max. 80 / Max. 176

Max. 80 / Max. 176

Max. 120 / Maz. 248

Max. 80 / Max. 176

Max. 140 / Max. 284

Temperature Fluctuation 1) 2)
at 100
( / )

0.3 / 0.54

0.3 / 0.54

0.3 / 0.54

0.3 / 0.54

0.3 / 0.54

Temperature
Variation 2)
/ )

at 100

0.4 / 0.72

0.4 / 0.72

1.3 / 2.34

0.5 / 0.90

0.5 / 0.90

at 150

0.7 / 1.26

0.7 / 1.26

2.3 / 4.14

0.7 / 1.26

0.8 / 1.44

at 200

1.1 / 1.98

1.1 / 1.98

3.2 / 5.76

1.1 / 1.98

1.2 / 2.16

at 250

1.7 / 3.06

1.7 / 3.06

4.1 / 7.38

1.5 / 2.70

1.7 / 3.06

Heating Time 2) (min.) from Amb. to 250

51

51

51

55

60

Recovery time 2)
after door was
opened (min.)

at 100

10.5

10.5

8

6.5

8

at 150

8

8

9

8

9.5

at 200

4.5

4.5

8.5

7

8.5

at 250

5

5

9.5

5.5

9.5

Air Change rate (approx, x/h)

213

266

173

233

193

Air Circulation (approx, x/h)

374

590

294

348

220

Exhaust air volume flow (approx, L/min)

380

1240

1400

1910

1560

Air flow velocity (m/s)

0.2 to 0.6

0.2 to 0.6

0.2 to 0.6

0.2 to 0.6

0.2 to 0.6

Dimension
(WxDxH)

Interior (mm / inch)

500×500×500
/ 19.7×19.7×19.7

600×650×650
/ 23.6×25.6×25.6

750×700×800
/ 29.5×27.6×31.5

900×800×1000
/ 35.4×31.5×39.4

1000×910×1100
/ 39.4×35.8×43.3

Exterior (mm / inch)

1100×745×1362
/ 43.3×29.3×53.6

1200×995×1559
/ 47.2×39.2×61.4

1350×1045×1712
/ 53.1×41.1×67.4

1500×1145×1912
/ 59×45.1×75.3

1600×1255×2012
/ 62.9×49.4×79.2

Net Weight 
(kg / lbs)

170 / 374.8

260 / 573.2

320 / 705.5

390 / 859.8

440 / 970

Interface Port

Basically RS-232C [RS-485(Maximum 32 Units Control)-optional]

Electrical Requirements (230V, 60Hz)

1ph / 14A

1ph / 21.3A

     

Cat. No.

AAHK1011K

AAHK1021K

-

-

-

Electrical Requirements (230V, 50Hz)

1ph / 14A

1ph / 21.3A

3ph / 16.2A

3ph / 20.7A

3ph / 24.6A

Cat. No.

AAHK1012K

AAHK1022K

AAHK10312K

AAHK10412K

AAHK10512K

Electrical Requirements (380V, 50Hz)

   

3ph / 9.4A

3ph / 12A

3ph / 14.2A

Cat. No.

-

 -

AAHK1038K

AAHK1048K

AAHK1058K

 

1) According to IEC 60068-3-5
2) According to DIN 12880
* Above specification value is recorded by 230V/60Hz, 380V/50Hz.
* Above specifications can be changed without prior notice.

 

Model

LTV-012

LTV-025

LTV-040

LTV-070

LTV-100

Chamber Volume (L / cu ft)

125 / 4.4

253 / 8.9

420 / 14.8

720 / 25.4

1000 / 35.3

Controller

Programmable, Touch screen type controller (3.5" Color monitor)

Temperature
Range (
/ )

intake/damper
100% close

Amb.+45 to 350 / Amb. +113 to 662

intake/damper
100% open

Max. 115 / Max. 239

Max. 115 / Max. 239

Max. 180 / Max. 356

Max. 150 / Max. 302

Max. 210 / Max. 410

Temperature Fluctuation 1) 2)
at 100
( / )

0.4 / 0.72

0.4 / 0.72

0.3 / 0.54

0.5 / 0.90

0.4 / 0.72

Temperature
Variation 2)
/ )

at 100

0.5 / 0.90

0.5 / 0.90

0.6 / 1.08

0.7 / 1.26

0.4 / 0.72

at 150

0.7 / 1.26

0.7 / 1.26

1.0 / 1.80

1.1 / 1.98

0.6 / 1.08

at 200

1.1 / 1.98

1.1 / 1.98

1.7 / 3.06

1.9 / 3.42

1.1 / 1.98

at 250

1.6 / 2.88

1.6 / 2.88

2.5 / 4.5

2.7 / 4.86

1.6 / 2.88

at 300

2.4 / 4.32

2.4 / 4.32

3.4 / 6.12

3.4 / 6.12

2.4 / 4.32

at 350

3.4 / 6.12

3.4 / 6.12

3.4 / 6.12

4.1 / 7.38

3.2 / 5.76

Heating Time 2) (min.) from Amb. to 350

41

41

43

40

45

Recovery time 2)
after door was
opened (min.)

at 100

8.5

8.5

6

6

7.5

at 150

8.5

8.5

9

7.5

9.5

at 200

3.5

3.5

8.5

8.5

8.5

at 250

5

5

11.5

8.5

9.5

at 300

7.5

7.5

12.5

8.5

9

at 350

8.5

8.5

12.5

10

10

Air Change rate (approx, x/h)

213

266

173

233

193

Air Circulation (approx, x/h)

374

590

294

348

220

Exhaust air volume flow (approx, L/min)

380

1240

1400

1910

1560

Air flow velocity (m/s)

0.2 to 0.6

0.2 to 0.6

0.2 to 0.6

0.2 to 0.6

0.2 to 0.6

Dimension
(WxDxH)

Interior (mm / inch)

500×500×500
/ 19.7×19.7×19.7

600×650×650
/ 23.6×25.6×25.6

750×700×800
/ 29.5×27.6×31.5

900×800×1000
/ 35.4×31.5×39.4

1000×910×1100
/ 39.4×35.8×43.3

Exterior (mm / inch)

1100×745×1362
/ 43.3×29.3×53.6

1200×995×1559
/ 47.2×39.2×61.4

1350×1045×1712
/ 53.1×41.1×67.4

1500×1145×1912
/ 59×45.1×75.3

1600×1255×2012
/ 62.9×49.4×79.2

Net Weight 
(kg / lbs)

170 / 374.8

260 / 573.2

320 / 705.5

390 / 859.8

440 / 970

Interface Port

Basically RS-232C [RS-485(Maximum 32 Units Control)-optional]

Electrical Requirements (230V, 60Hz)

1ph / 27.6A

       

Cat. No.

AAHK2011K

       

Electrical Requirements (230V, 50Hz)

1ph / 27.6A

3ph / 24.1A

3ph / 32A

3ph / 40.3A

3ph / 48.2A

Cat. No.

AAHK2012K

AAHK20212K

AAHK20312K

AAHK20412K

AAHK20512K

Electrical Requirements (380V, 50Hz)

 

3ph / 13.9A

3ph / 18.5A

3ph / 23.4A

3ph / 27.9A

Cat. No.

 -

AAHK2028K

AAHK2038K

AAHK2048K

AAHK2058K

 

1) According to IEC 60068-3-5
2) According to DIN 12880
* Above specification value is recorded by 230V/60Hz, 380V/50Hz.
* Above specifications can be changed without prior notice.

 

  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.

Payment:   credit
Subscribethe newletter PROMOTIONS
© Copyright 2004 - 2015 of Red Star Vietnam Co., Ltd.