● Insensitive to Vibrations and Ambient Light
● Amazingly Fast Scanning Speed - 16,000 Wavelengths per Second
● No Moving Parts
● Non-Invasive, Contactless Measurement
● Superior Signal-to-Noise Ratio Throughout the Entire Spectral Range
Spectrometer Name |
Luminar 3030 Free Space AOTF-NIR Process Analyzer |
Spectral Range Options |
600-1100nm, 850-1700 nm, 900-1800 nm, 1100-2300 nm |
Measurement Modes |
DiffuseReflection, (Transmission with an attachment) |
Spectral Resolution |
5-10nm |
Wavelength Accuracy |
± 0.5 nm |
Wavelength Repeatability |
± 0.01 nm |
Wavelength Increment |
Software Selectable 1-10 nm |
Ambient Light Rejection |
> 106 |
Non-Linearity |
0.1% |
Signal Digitalization |
16-bitA/D(1 part in 65,536) |
Sampling Speed |
16,000 wavelength/sec |
Sampling Area |
26x 16 mm (Model 700), 9 x 5 mm (Model 701), 5 x 3 mm (Model 705) |
Sampling Angle |
25° |
Process Control |
Upto 16 A/D, 16 D/A Channels and 16 I/O Channels accessed via MACRO language, D/A outputs can be supplied as isolated 4-20 mA current loop outputs - Modbus capability (optional) (RS 422/485) |
Diagnostic |
10Built-in monitoring sensors |
Power Requirements |
100-240VAC, 50/60 Hz, 90 Watts |
Software Package |
Windows-based analytical software for data acquisition |
|
|
|
Attachments: |
|
700-23For conversion to lab diffuse reflectance 700-25For conversion to lab transmission measurement 700-26 Air-Flow Curtain 705-20For transmission measurement |
● Pharmaceutical: 100% inspection of solids, pastes, creams and powders
● Agricultural and Food: In-line food analysis for fat, protein, moisture
● Polymer: In-site measurement of pellets, films, and coatings
● Drying Process: Direct placement on spray or fluid-bed dryers
● Pulp and Paper: In-line thickness and coating analysis
● 700 - Free space optical head for 26x16mm sample area
● 701 - Free space optical head for 9x5mm sample area at 65mm working distance
● 705 - Free space optical head for 5x3mm sample area at 42.5mm working distance
● 700-23 - For conversion to lab diffuse reflectance
● 700-25 - For conversion to lab transmission measurement
● 700-26 - Air-Flow Curtain
● 705-20 - For transmission measurement
● Wavelength Range
● Cable length between free space optical head and electronics enclosure (Max: 10 meters)
● 700-26 - Air-flow Curtain
● 700-23 - Attachment for Conversion to Lab Diffuse Reflectance Measurement
● 700-25 - Attachment for Conversion to Lab Transmission Measurement
● Purging System (for Explosion-proof Models)
● IQ/OQ Documents
● PERFTEST Software
● NIRPQMS Additional Software Package (21 CFR 11 Compliant)
● Training and Installation Support
● 760 - Electronics for one chassis, vortex cooled NEMA 4X enclosure
● 761 - Electronics for one chassis, TE cooled NEMA 4X enclosure
● 763 - Electronics for one chassis, fan cooled 19” rack-mount enclosure
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.