Parameter | Range | Resolution | Accuracy |
Temp Measurement Flue Temperature Inlet Temperature (Internal sensor) Inlet Temperature (External sensor) |
0-600°C 0-50°C 0-600°C |
0.1°C 0.1°C 0.1°C |
±2.0°C ±0.3% reading ±1.0°C ±0.3% reading ±2.0°C ±0.3% reading |
Gas Measurement Oxygen*2 Carbon monoxide Carbon dioxide Efficiency (Net or Gross) *2 Efficiency High (C) *2 Excess Air *2 CO/CO2 ratio *2 |
0-21% 0-20ppm 0-2,000ppm nom 4,000ppm max for 15 mins 0-20% 0-99.9% 0-119.9% 0-250% 0-0.999 |
0.1% 1ppm 0.1% 0.1% 0.1% 0.1% 0.0001 |
±0.3%*1 ±3ppm ±5% reading ±0.3% reading ±1.0% reading ±1.0% reading ±0.2% reading ±5% reading |
Pressure (differential) Nominal range ±80mBar Maximum over range without damage to sensor is ±400mBar |
±0.2 mBar ±1 mBar ±80 mBar |
0.001 mBar < 25mBar |
±0.005 mBar ±0.03 mBar ±3% of reading |
1 Using dry gases at STP - 2 Calculated
Pre-programmed Fuels |
Natural gas, Propane, Butane, LPG Light Oils (28/35 sec), Wood Pellets |
Storage Capacity |
99 Combustion tests |
Ambient Operating Range |
0oC to +40oC 10% to 90% RH non-condensing |
Chargers (optional) |
220v charger, for NiMH batteries only |
Dimensions |
0.8kg handset with boot |
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.