Category | Functions | Descriptions | Details |
---|---|---|---|
Amplifier | Measurement Channel | Vibration Input ×6 (CH1 ~ CH6) Voltage Input ×2 (CH7 ~ CH8) |
Voltage Inputs from Servo type Accelerometer (Single Axis type, 3 Axis type), Noise Level meter, Pressure meter, Thermo meter, |
Input Combination | CH1 ~ CH6 AC/DC CH7 ~ CH8 DC |
CH1 ~ CH6 AC: 0.1Hz ~DC, :Zero Adjustment・Gravity Acceleration Cancellation DC only CH7 ~ CH8 DC only |
|
Frequency Response | CH1~CH6 0.1Hz/DC~12Hz(±0.5dB) 0.1Hz/DC~30Hz(±0.5dB) 0.1Hz/DC~60Hz(±0.5dB) CH7~CH8 DC~12Hz(±0.5dB) DC~50Hz(±0.5dB) |
CH1 ~ CH6 Variable Low-pass filter to be set as fc=20Hz. 50Hz. 100Hz CH7 ~ CH8 Low-pass filter to be set on or off of fc=20KHz |
|
Measurement Range | CH1 ~ CH6 0.01m/s2・0.1m/s2・1m/s2・ 10m/s2 CH7 ~ CH8 ±5V Full Scale Voltage Signal |
― | |
Output Signal | ±5V Full Scale Voltage Waveform Signal |
2 Signal Routes (for Recorder, for Waveform Data Acquisition, Analysis) |
|
Linearity | ±0.5% Full Scale | ― | |
Inter Range Error | ±2% | ― | |
S / N Ratio | 60dB~100dB or more | >100dB(Measurement Range:10m/s2) | |
>96dB(Measurement Range:1m/s2) | |||
>80dB(Measurement Range:0.1m/s2) | |||
>60dB(Measurement Range:0.01m/s2) | |||
Calibration Signal Output | 12Hz Full Scale equivalent | Calibrated for 0.01m/s2 Range | |
External Control | Measurement Range Low-pass Filter | Controlled by TTL level Signal | |
Power | 9 ~12VDC, 2A | ― | |
Power Consumption | 4W | Increases by(0.8×Axis Number) watts connected with Pickups | |
Ambient Environment | 0~+50℃ | ― | |
Outer Size | 240(W) x 150(D) x 35(H) mm | ― | |
Mass | Approx 920g | ― |
Category | Function | Content | Details |
---|---|---|---|
Hardware | Output cable | Mini plug - BNC 1.5m | ― |
Battery pack | Continuous Operation : ≧3hrs. for 6ch Measurement |
Battery for Lap top |
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.