Servo-Acceleration Vibration Pickup | Color Display | Seismic intensity.SI Value Alarm Contact Output | Extra Alarm Output |
3-direction non-directivity | History Report | FAULT Alarm | |
Earthquake infomation Display | Alarm Buzzer | Alarm External Reset | Connection with Extarnal Display |
Acceleration Alarm Contact Output | Backup for Power Cut | Analogue Level Output | Pickup Test |
The functions displayed by gray colour are excluded.
[Touch panel type]Direct operation makes speedy conrirm. |
[Easy fixing]
U-shaped fixing hole makes easy |
[System Calibration Service]Calibration system is composed of a compact electrodynamic horizontal table PET-03 and an amplifier with oscillator PET-OA. It can simulate earthquake and enables an easy calibration test. |
[Compact design]By locating pick-up port at a lower place and rounding off the corners, we are able avoid impact to cables from outside. |
[Water-proof type]IP67 water proof compliant structure enables installation at |
[History Report Screen]History up to 50 are saved. |
[Safety and high accuracy]This is the most advanced of all electrical type. Servo sensors can detect acceleration fromO Hz. |
Model |
SW-74 |
Display Element |
STN monochrome LCD with touch switch |
Earthquake monitor screen |
Present time |
Earthquake generation screen |
Earthquake generation time, Mex. acceleration, Seismic intensity scale, Alarm operation |
Alarm hold screen |
Reset button (Whole reset of alarm/buzzer) |
Each setting screen |
Trigger, Alarm, Date/time |
Maintenance screen |
Pickup test, Earthquake history |
Alatm & Buzzer |
Upper 3-step (ALM1-3) Individual setting, |
Alarm & Buzzer Reset Method |
a. External reset terminal (All step reset by no-voltage a contact) |
Fault Alarm |
[Power failure] 1a/1b contact switching type Contact rating: 2A 30VDC (Max. allowance voltage/current : 220VDC/2A) |
Serial Output |
For maintenance (conforms to RS232C) : MC1 (Switching type with screen control) |
Back-up Unit |
Backup time ≧10min (ready time), Charging time ≦48hrs (No function at the operation by optional power 24VDC) |
Mounting Method |
Wall type |
Ambient Temperature |
0~+50℃ |
Humidity Range |
10~85%RH |
Power Supply |
100VAC±10%, ≦50VA 24VDC±10%, ≦35W(option) |
Outer Dimensions |
See the outside view |
Painted Color |
Panel:Similar to Munsell 5GY8/0.5 Case: Munsell N6.0 |
Weight |
3kg approx. |
Options to expand the function are provided.
Indicates Acceleration value, Seismic intensity scale and Alarm generation time. |
Takes out the alarm when 2-sets among 3-sets operate. |
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.