The Agilent HS-16 Diffusion Pump

State: In stock
Available in 2 in. and 16 in. through 35 in. sizes, the low-cost HS-series pumps provide high speed, low ultimate pressure, high throughput, high tolerable forepressure, and low backstreaming. The HS-Series diffusion pumps come with full thermal protection and optional quick-cool coils. The 16 in. through 35 in. pumps come with sight glass/fill and drain assemblies, and are available with ASA or ISO flanges.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week
Features
  • Five-stage fractionating jet purifies pumping fluid
  • High throughput, 9600-watt version available
  • High tolerable forepressure
  • Full thermal protection
  • Fill and drain assembly for pump oil
  • Fluid-level sight glass provides quick indication of pump fluid status at all times
  • Standard gauge port (NW-25) below inlet flange included
  • Foreline baffle prevents loss of fluid into backing pump system
  • Optional halo baffle reduces backstreaming without adding height
  • Optional quick cool coil

 

Order Information

Part Number Description
K9050002 Thermostat, lower switch, set at 199 °C, for HS-16 and HS-20 diffusion pumps
K9050001 Thermostat, upper switch, set at 85 °C, for HS-16 and HS-20 diffusion pumps
K0143316 Halo baffle, 16 inch, for HS-16 diffusion pump
K0377164 O-ring kit, for HS-16 diffusion pump
K4917001 Heater clamp plate, HS-16 diffusion pump
K4919001 Heater crush plate, HS-16 diffusion pump
L5921308 HS-16 diffusion pump, ISO, standard cold cap, 240 V, 8100 W
L5921309 HS-16 diffusion pump, ISO, standard cold cap, 480 V, 8100 W
L5921318 HS-16 diffusion pump, ISO, halo baffle, 240 V, 8100 W
L5921319 HS-16 diffusion pump, ISO, halo baffle, 480 V, 8100 W
L5921326 HS-16 diffusion pump, ISO, standard cold cap, 415 V, 8100 W
L5921336 HS-16 diffusion pump, ISO, halo baffle, 415 V, 8100 W
L6526309 Heater retrofit kit, HS-16 diffusion pump, 480 V
L6526326 Heater retrofit kit, HS-16 diffusion pump, 380/415 V
79292308 HS-16 diffusion pump, with standard cold cap, 240 V, 8100 W wired Delta Parallel, ASA flange
79292309 HS-16 diffusion pump, with standard cold cap, 8100 W, 480V wired Delta Series, ASA flange
79292318 HS-16 diffusion pump, with Halo Baffle, 240 V, 8100 W wired Delta Parallel, ASA flange
79292319 HS-16 diffusion pump, with Halo Baffle, 480 V, 8100 W wired Delta Series, ASA flange
79292326 HS-16 diffusion pump, with standard cold cap, 415 V, 8100 W, wired WYE Parallel, ASA flange
79292336 HS-16 diffusion pump, with Halo Baffle, 380/415 V, 8100 W, wired WYE Parallel, ASA flange
79309001 Heater insulator, for HS-16 diffusion pump
647316020 Heater, HS-16 diffusion pump, 240//415 V, 2700 W, with leads
647316023 Heater, HS-16 diffusion pump, 240/415 V, 3200 W, with leads
647316030 Heater, HS-16 diffusion pump, 480 V, 2700 W, with leads
L6526309 Heater retrofit kit, HS-16 diffusion pump, 480 V
L6526326 Heater retrofit kit, HS-16 diffusion pump, 380/415 V
79292308 HS-16 diffusion pump, with standard cold cap, 240 V, 8100 W wired Delta Parallel, ASA flange
79292309 HS-16 diffusion pump, with standard cold cap, 8100 W, 480V wired Delta Series, ASA flange
79292318 HS-16 diffusion pump, with Halo Baffle, 240 V, 8100 W wired Delta Parallel, ASA flange
79292319 HS-16 diffusion pump, with Halo Baffle, 480 V, 8100 W wired Delta Series, ASA flange
79292326 HS-16 diffusion pump, with standard cold cap, 415 V, 8100 W, wired WYE Parallel, ASA flange
79292336 HS-16 diffusion pump, with Halo Baffle, 380/415 V, 8100 W, wired WYE Parallel, ASA flange
79309001 Heater insulator, for HS-16 diffusion pump
647316020 Heater, HS-16 diffusion pump, 240//415 V, 2700 W, with leads
647316023 Heater, HS-16 diffusion pump, 240/415 V, 3200 W, with leads
647316030 Heater, HS-16 diffusion pump, 480 V, 2700 W, with leads

 

Technical Specifications

 

Pumping speed, operating range 6,000 l/s air, 7,500 l/s He and H2
Pumping speed*, AVS 4.1(1963) 10,000 l/s air
Maximum throughput 8,100 W – 9.5 T-l/s (12.7 mbar l/s) in operating range13.5 T-l/s (18.0 mbar-l/s) @ 0.01 Torr
9,600 W –12.0 T-l/s (16 mbar l/s) in operating range 11.5 T-l/s (15.3 mbar-l/s) @ 0.01 Torr
Operating range 2 x 10-3 to
Maximum forepressure No load – 0.65 Torr (0.85 mbar), Full Load – 0.55 Torr (0.72 mbar)
Pump power 8100/9600 watts
Recommended backing pump ≥ 80 cfm (136 m3/hr)
Backstreaming rate**, standard cold cap  
Warmup time 30 minutes
Cooldown time 48 minutes (30 minutes with optional quick cool coil)
Fluid charge 3 quarts (2.8 liters)
Electrical requirements 3 ph, 50/60 Hz, 240/415/480 VAC
Cooling water requirements 1.5 gpm (300 l/hr) at 60-80 °F (15-26 °C)
Water connections 1⁄4 in. FPT Tee
Recommended fluid DC-704 (see page 30 of catalog)

* For an explanation of pumping speed measurements, please see catalog page 36.
** Refer to catalog page 34 for a description of test methods

 

Outline Drawing

 

 

 

  • Đánh giá sản phẩm:

(Xem mã khác)

Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.

Payment:   credit
Subscribethe newletter PROMOTIONS
© Copyright 2004 - 2015 of Red Star Vietnam Co., Ltd.