Agilent IDP dry scroll pumps are oil-free, compact, quiet, high performance vacuum pumps. IDP pumps use a single-sided scroll design that allows for a straightforward 15 minute maintenance procedure with simple tools. Large pumping speeds and compact sizes are ideal for many applications in the research, analytical instrument, and laboratory markets.
IDP pumps are hermetic, with the motor and all bearings completely isolated from the vacuum path. This design extends the bearing life and provides clean, dry vacuum to the application. An inlet isolation valve is available as an integral option that adds no additional height to the pump. The IDP-10 uses an inverter driven motor, which provides uniform vacuum performance at all global frequencies and input voltages. Its uniform global performance and compact size make it an ideal choice for analytical instruments and industrial OEMs.
IDP Family Dry Scroll Pumps | Pumping Speed | Base Pressure | Motor Rating/Operating Voltage | Common Applications | Choose this model if... |
---|---|---|---|---|---|
IDP-3 | 60 Hz/24 VDC: 60 l/m, 3.6 m3/hour 50 Hz: 50 l/m, 3.0 m3/hour |
3.3 x 10-1 mbar, 2.5 x 10-1 Torr | 0.16 HP (120 W)/100-120; 200-240 VAC |
|
|
IDP-7 | 60 Hz: 152 l/m, 9.1 m3/hour 50 Hz: 120 l/m, 7.2 m3/hour |
60 Hz: 2.6 x 10-2mbar 2.0 x 10-2 Torr 50 Hz: 4.0 x 10-2mbar, 3.0 x 10-2Torr |
0.38 HP (300 W)/100-120; 200-240 VAC |
|
|
IDP-10 |
170 L/min, 10.2 m3/h
at full rotational speed
|
2.0 x 10-2 mbar 1.5 x 10-2 Torr | 0.5 HP (350 W)/100-127; 200-240 VAC |
|
|
IDP-15
|
60 Hz>: 256 l/m, 15.4 m3/hour 50 Hz: 214 l/m, 12.8 m3/hour |
1.33 x 10-2 mbar 1 x 10-2 Torr | 0.75 HP (560 W)/100-115; 220-230 VAC |
|
|
Add the inlet isolation valve if... |
|
|
Media | No corrosive, explosive or particulate forming gases |
Maximum inlet pressure | 1.0 atmosphere (0 psig) |
Recommended max inlet pressure | 200 mbar (150 Torr) |
Maximum outlet pressure | IDP-3 and IDP-15: 1.4 atmosphere (6.5 psig) |
IDP-7 and IDP-10: 1.34 atmosphere (5 psig) | |
Inlet connection | IDP-3: NW16 |
IDP-7, IDP-10, IDP-15: NW25 | |
Exhaust connection | IDP-3: female, 0.25 inch, national pipe thread; 10 mm hose barb provided installed |
IDP-7 and IDP-10: NW16 | |
IDP-15: female, 0.25 inch, national pipe thread (NW16 adapter provided) | |
Gas ballast | IDP-3. IDP-7, and I DP-1 0: female, 0.25 inch national pipe thread (shipped with gas ba llast port plug installed; 20 μm sintered filter provided) |
IDP-15: female, 0.25 inch, national pipe thread (two position~) | |
Water vapor handling per Pneurop 6602 (maximum) | IDP-7 and IDP-10: 120/h |
IDP-15: 235/h | |
Ambient operating temperature | 5 to 40 °C ( 41 to 1 04 °f) |
Storage temperature | - 20 to 60 °C (-4 to 140 °f) |
Motor thermal protection | Automatic thermal protection |
Cooling system | Air-cooled |
leak rate (with exhaust sealed) | |
Vibration level at inlet (per ISO 10816-1) | IDP-3: 5 mms·1 rms |
IDP-7 and IDP-10: 7 mms·1 rms | |
IDP-15: < 9 mms·1 rms | |
Hour meter | Integral hour meter provided |
Emissions and immunity | EN61236-1: 2013 as a Class A device |
Safety | EN/IEC 61010 3rd Edition certified |
Ambient relative humidity | 5-90 %; noncondensing |
Installation | Indoor use, installation category II. pollution degree 2 |
Altitude | 2000 m (6562 feet) |
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.