The Agilent IDP Dry Scroll Pumps

State: In stock
Agilent IDP dry scroll pumps are oil-free, compact, quiet, high performance vacuum pumps. IDP pumps use a single-sided scroll design that allows for a straightforward 15 minute maintenance procedure with simple tools. Large pumping speeds and compact sizes are ideal for many applications in the research, analytical instrument, and laboratory markets.
Warranty: No warranty infomation


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

Agilent IDP dry scroll pumps are oil-free, compact, quiet, high performance vacuum pumps. IDP pumps use a single-sided scroll design that allows for a straightforward 15 minute maintenance procedure with simple tools. Large pumping speeds and compact sizes are ideal for many applications in the research, analytical instrument, and laboratory markets. 

IDP pumps are hermetic, with the motor and all bearings completely isolated from the vacuum path. This design extends the bearing life and provides clean, dry vacuum to the application. An inlet isolation valve is available as an integral option that adds no additional height to the pump. The IDP-10 uses an inverter driven motor, which provides uniform vacuum performance at all global frequencies and input voltages. Its uniform global performance and compact size make it an ideal choice for analytical instruments and industrial OEMs.

 

Features
 
IDP Family Dry Scroll PumpsPumping SpeedBase PressureMotor Rating/Operating VoltageCommon ApplicationsChoose this model if...
IDP-3 60 Hz/24 VDC: 60 l/m, 3.6 m3/hour
50 Hz: 50 l/m, 3.0 m3/hour
3.3 x 10-1 mbar, 2.5 x 10-1 Torr 0.16 HP (120 W)/100-120; 200-240 VAC
  • Leak Detection
  • GC Mass Spectrometry
  • Helium Recirculation
  • You want the lightest, most compact primary pump
  • You need to integrate the pump into your instrument
  • You want a 24V drive
  • You have an Agilent GC/MS
IDP-7 60 Hz: 152 l/m, 9.1 m3/hour
50 Hz: 120 l/m, 7.2 m3/hour
60 Hz: 2.6 x 10-2mbar
2.0 x 10-2 Torr
50 Hz: 4.0 x 10-2mbar, 3.0 x 10-2Torr
0.38 HP (300 W)/100-120; 200-240 VAC
  • Vacuum Ovens
  • Helium Recirculation
  • Backing High Vacuum Pump
  • General Laboratory Vacuum
IDP-10
170 L/min, 10.2 m3/h
at full rotational speed
2.0 x 10-2 mbar 1.5 x 10-2 Torr 0.5 HP (350 W)/100-127; 200-240 VAC
  • Microscopy Instruments
  • Surface Analysis Instruments
  • Helium Recirculation
  • Thin Film Deposition
IDP-15

 

60 Hz>: 256 l/m, 15.4 m3/hour
50 Hz: 214 l/m, 12.8 m3/hour
1.33 x 10-2 mbar 1 x 10-2 Torr 0.75 HP (560 W)/100-115; 220-230 VAC
  • General Laboratory Vacuum
  • Thin Film Deposition
  • LED, Bulb Manufacturing
  Add the inlet isolation valve if...
  • Instrumentation
  • Beam and Particle Physics
  • Backing a Turbo Pump
  • You want to protect your system and high vacuum pump in case of power loss
  • You want to isolate the pump inlet during turbulent stop and start

 
Media No corrosive, explosive or particulate forming gases
Maximum inlet pressure 1.0 atmosphere (0 psig)
Recommended max inlet pressure 200 mbar (150 Torr)
Maximum outlet pressure IDP-3 and IDP-15: 1.4 atmosphere (6.5 psig)
IDP-7 and IDP-10: 1.34 atmosphere (5 psig)
Inlet connection IDP-3: NW16
IDP-7, IDP-10, IDP-15: NW25
Exhaust connection IDP-3: female, 0.25 inch, national pipe thread; 10 mm hose barb provided installed
IDP-7 and IDP-10: NW16
IDP-15: female, 0.25 inch, national pipe thread (NW16 adapter provided)
Gas ballast IDP-3. IDP-7, and I DP-1 0: female, 0.25 inch national pipe thread (shipped with gas ba llast port plug installed; 20 μm sintered filter provided)
IDP-15: female, 0.25 inch, national pipe thread (two position~)
Water vapor handling per Pneurop 6602 (maximum) IDP-7 and IDP-10: 120/h
IDP-15: 235/h
Ambient operating temperature 5 to 40 °C ( 41 to 1 04 °f)
Storage temperature - 20 to 60 °C (-4 to 140 °f)
Motor thermal protection Automatic thermal protection
Cooling system Air-cooled
leak rate (with exhaust sealed)  
Vibration level at inlet (per ISO 10816-1) IDP-3: 5 mms·1 rms
IDP-7 and IDP-10: 7 mms·1 rms
IDP-15: < 9 mms·1 rms
Hour meter Integral hour meter provided
Emissions and immunity EN61236-1: 2013 as a Class A device
Safety EN/IEC 61010 3rd Edition certified
Ambient relative humidity 5-90 %; noncondensing
Installation Indoor use, installation category II. pollution degree 2
Altitude 2000 m (6562 feet)