Coolstage -25°C to +50°C for high & low vacuum SEMs

State: Out of stock
With increased use of Low Vacuum or Variable Pressure microscopes, many microscopists now appreciate the need to control water evaporation from wet samples. By cooling a wet specimen, water evaporation may be slowed or depending on chamber pressure stopped altogether.
Warranty: 12 tháng


Price: Contact us




Order
  • Delivery time: 8h00 - 18h00 daily
  • Genuine product, provided width CO, CQ
  • 03 months of free warranty for consumable and accessories
  • 12 months of free warranty for main equipment
  • Accessorie's price is applied only when purchased with
    main equipment
  • Contact us for any particular accessory's quotion
Email: info@redstarvietnam.com Every day in week

Saturated vapour pressure of water decreases considerably with temperature. At room temperature water will very quickly evaporate causing considerable changes to the specimen structure. At 300Pa, specimen temperature needs to be less than -9.5°C and at 85Pa specimen temperature needs to be less than -25°C to stop water evaporation. Therefore by cooling a specimen to -25°C, chamber pressure may by 85Pa with minimal water evaporation from the specimen. Advantages of this procedure are clear to see, by cooling a specimen in low vacuum, changes in specimen structure due to water evaporation can be minimised and the ability to operate at higher vacuum provides a better signal to noise ratio and clearer images.

 

The Deben Coolstage is available for all SEMs and guaranteed temperature range is +50°C to -25°C (at 300Pa chamber pressure) or less that -25°C at higher vacuums.

 

 

Applications

 

Why cool samples? With increased use of Low Vacuum or Variable Pressure microscopes, many microscopists now appreciate the need to control water evaporation from wet samples. By cooling a wet specimen, water evaporation may be slowed or depending on chamber pressure stopped altogether. Saturated vapour pressure of water decreases considerably with temperature.

 

At room temperature water will very quickly evaporate causing considerable changes to the specimen structure. At 300Pa, specimen temperature needs to be less than -9.5°C and at 85Pa specimen temperature needs to be less than -25°C to stop water evaporation. Therefore by cooling a specimen to -25°C, chamber pressure may be 85Pa with no water evaporation from the specimen. Advantages of this procedure are clear to see, by cooling a specimen in low vacuum, changes in specimen structure due to water evaporation can be minimised and the ability to operate at higher vacuum provides a better signal to noise ratio and clearer images.

 

The Deben Coolstage can also be used for high vacuum heating and cooling applications inside the SEM.