● Development, design, production: 100 % Trotec
● Non-contact surface temperature measurement from -50 °C to +1,000 °C
● Measuring optic 30:1
● Optimum price-performance-ratio
● Measuring spot diameter display due to dual laser technology
● Degree of emission freely adjustable from 0.1 to 1.0
● Maximum value and hold function
● Backlit display
● Alarm function
● Automatic switch-off
Impressive technical performance data, e.g. a temperature measuring range from -50 °C to +1,000 °C, a high optical resolution of 30:1 or the innovative dual laser combined with a remarkable price-performance-ratio, make the TP7 a universal professional infrared thermometer for manifold fields of application.
The TP7 enables the material-specific adjustment of the degree of emission and comes equipped with a brilliant, backlit display for fatigue-proof reading of measured values even in poorly illuminated environments.
Moreover, the TP7 impresses with numerous professional equipment features, e.g. alarm function with freely definable limit values, non-stop measuring mode and functions to hold the current measured value as well as for the determination and display of the maximum value.
Particularly convenient application offers the innovative dual laser of the TP7, which automatically visualizes the size of the measuring spot. The distance between both laser beams corresponds to the measuring spot's diameter.
Owing to the high temperature measuring range and the non-contact measurement principle, the robust TP7 is ideally suited for temperature measurements at poorly accessible, hot, movable or dangerous measuring points.
Thanks to the improved optics, even smaller objects can be measured from further away.
Master data |
|
Article number |
3.510.003.011 |
Optics |
|
Optical resolution |
30:1 |
Smallest measuring spot |
25,4 mm @ 762 mm |
Temperature sensor infrared [°C] |
|
Min. measuring range |
-50 |
Max. measuring range |
1.000 |
Accuracy, max. |
— |
Accuracy < -4 °C |
— |
Accuracy -4 °C to 65 °C |
— |
Accuracy > 65 °C |
— |
Accuracy < 20 °C |
— |
Accuracy = 20 °C |
— |
Accuracy @ @ -50 °C to 20 °C (-58 °F to 68 °F) |
± 2,5 |
Accuracy @ 21 °C to 300 °C |
± 1 |
Accuracy @ 301 °C to 1,000 °C |
± 1,5 |
Accuracy @ 21 °C to 400 °C |
— |
Accuracy @ 401 °C to 800 °C |
— |
Accuracy @ 800 °C to 1,600 °C |
— |
Repeatability at -50 °C to 20 °C |
± 1,3 |
Repeatability at 21 °C to 1,000 °C |
± 0,8 oder ± 0,5 |
Repeatability at 21 °C to 1,200 °C |
— |
Repeatability at 1,201 °C to 1,600 °C |
— |
Accuracy @ 20 °C to 500 °C (68 °F to 932 °F) |
— |
Accuracy @ 500 °C to 1,000 °C (932 °F to 1,832 °F) |
— |
Accuracy @ 1,000 °C to 1,850 °C (1832 °F to 3,362 °F) |
— |
Repeatability at 20 °C to 1,000 °C (68 °F to 1,832 °F) |
— |
Repeatability at 1,000 °C to 1,850 °C (1832 °F to 3,362 °F) |
— |
Temperature sensor infrared [°F] |
|
Min. measuring range |
-58 |
Max. measuring range |
1.832 |
Accuracy, min. |
4,5 (± 1 % vom Messwert) |
Accuracy, max. |
± 1 % from the measured value |
Integrated temperature sensor [°C] |
|
Min. measuring range |
— |
Max. measuring range |
— |
Accuracy, min. |
— |
Accuracy, max. |
— |
Integrated temperature sensor [°F] |
|
Min. measuring range |
— |
Max. measuring range |
— |
Accuracy < 23 °F to 150 °F |
— |
Accuracy > 150 °F |
— |
Dew point temperature [°C] |
|
Min. measuring range |
— |
Max. measuring range |
— |
Accuracy |
— |
Humidity [%] |
|
Min. measuring range |
— |
Max. measuring range |
— |
Accuracy |
— |
Surrounding conditions |
|
Operation – min. temperature [°C] |
0 |
Operation – max. temperature [°C] |
50 |
Operation – min. relative humidity [%] |
10 |
Operation – max. relative humidity (non-condensing) [%] |
90 |
Storage – min. temperature [°C] |
-10 |
Storage – max. temperature [°C] |
60 |
Storage – max. relative humidity (non-condensing) [%] |
<80 |
Display |
|
LCD |
√ |
Monochrome |
— |
Interfaces |
|
USB |
— |
Plug connection for type K temperature sensor |
— |
Memory organization |
|
Internal Flash memory |
— |
Device control |
|
Push buttons |
√ |
Membrane keyboard |
— |
Type of protection |
|
IP65 |
— |
IP54 |
√ |
Temperature sensor |
|
Reaction time |
< 150 ms |
Spectral sensitivity |
8 ~ 14 µm |
Laser (target display) |
|
Class |
Class 2 |
Wavelength [nm] |
630 ~ 670 |
Power [mW] |
< 1 |
Power supply |
|
Internal (battery) |
9V block battery |
External (USB) |
— |
Housing design |
|
Plastic |
√ |
Weight (packing excluded) |
|
Weight [kg] |
0,163 |
Dimensions (packing excluded) |
|
Length [mm] |
104 |
Width [mm] |
43 |
Height [mm] |
146 |
STANDARD SCOPE OF DELIVERY |
||
Transport bag |
||
|
Option |
√ |
Battery(-ies) |
||
|
Option |
√ |
Operating manual |
||
|
Option |
√ |
Contact temperature sensor type K |
||
|
Option |
— |
Carrying case |
||
|
Option |
— |
USB cable |
||
|
Option |
— |
Mini tripod |
||
|
Option |
— |
ASCERTAINABLE MEASURED VALUES AND FUNCTIONS |
|
Internal sensors |
|
Material temperature [°C] |
√ |
Material temperature [°F] |
√ |
Dew point temperature [°C] |
— |
Dew point temperature [°F] |
— |
Air temperature [°C] |
— |
Air temperature [°F] |
— |
Relative humidity [%] |
— |
Functions and equipment |
|
Connectable dual laser |
√ |
Switching function for temperature measuring units °C/°F |
√ |
Display resolution 0.1°C |
√ |
Non-stop measuring function |
√ |
Maximum value display |
√ |
Minimum value display |
— |
Hold function |
√ |
Differential value display |
— |
Alarm function with user-defined limit values |
√ |
Acoustic alarm function |
√ |
HACCP quick indicator LED |
|
Degree of emission adjustable from 0.1 to 1.0 |
√ |
Backlit LCD monitor |
√ |
Automatic switch-off |
√ |
Maximum value indication |
— |
Open targeting sights |
— |
Additional temperature measurement using external type K sensor |
— |
Additional material temperature measurement using integrated type K insertion sensor |
— |
Applicable for software-supported recording of measurement series |
— |
Tripod thread connection |
— |
Meets the specifications of the LFGB, §31 (German Food and Feed Code) |
— |
Conforms with DIN 10955:2004 |
— |
Connectable single laser pointer |
— |
Battery status indicator |
— |
Degree of emission fixed at 0.95 |
— |
Acoustic dew point alarm |
— |
Visual dew point alarm |
— |
Timer function |
— |
Bar graph indicator for the quick identification of condensation risks |
— |
Hiện tại chưa có ý kiến đánh giá nào về sản phẩm. Hãy là người đầu tiên chia sẻ cảm nhận của bạn.