Tình trạng: Liên hệ
The Cool D-B80 A/P coil is designed for double-blinded clinical/research studies with one active (A) and one placebo (P) side. It is symmetrical in the design with no indication of which side is the active/placebo side.
Bảo hành: Chưa có thông tin bảo hành


Giá bán: Liên hệ




Đặt hàng
  • Khung giờ giao hàng từ 8h00 - 18h00 hàng ngày.
  • Sản phẩm chính hãng, cung cấp CO & CQ.
  • Bảo hành miễn phí 12 tháng với máy chính.
  • Giá trên chỉ áp dụng đối với mặt hàng có sẵn.
    Đối với mặt hàng không có sẵn sẽ tính thêm phí vận chuyển.
Gửi email yêu cầu báo giá: info@redstarvietnam.com            Tất cả các ngày trong tuần
  • Active side has electrical and magnetic properties like the D-B80 and the Cool D-B80.
  • The Cool D-B80 A/P coil is designed for double-blinded clinical/research studies with one active (A) and one placebo (P) side. It is symmetrical in the design with no indication of which side is the active/placebo side. 
  • The coil has a built-in orientation-switch to determine which side of the coil to be placed towards the patient (screen prompt on the MagPro if used with the rTMS Research software).
  • The coil is equipped with adjustable output for current stimulation of the patient's skin synchronously with the magnetic stimulation pulses.
  • The coil is suitable for deep stimulation due to the 120° angled surface and large windings.  The coil is further designed for demanding stimulation protocols requiring a very high number of stimuli.
  • Built in EPV timer and counter (5 years or 18 million EPV, whichever comes first).

 

When purchasing the Cool D-B80 coil the accessories for conducting truly double-blinded clinical research trials are enclosed (electrode cables, electrodes etc.). The use of all our A/P coils requires the Research Software USB-less to be installed on the MagPro.

 

Mechanical Properties

 

  • Weight of transducer head: 3.3 kg
  • Dimensions of transducer head: 220 x 115 x 150mm  
  • Thickness 30 mm
  • Angle 120°
  • Cable length: 2 m

 

 

Coil Winding Data

 

  • Inner diameter 67mm
  • Outer diameter 95mm
  • Winding height 12mm
  • Number of windings 2x (3+4)

 

 

Magnetic and Electrical Properties

 

  • Max initial dB/dt 31 kT/s near the coil surface.
  • Active pulse width 280µs (Biphasic)

 

 

Performance

 

  • Number of stimulations, before warm-up at ambient temperature 20°C, output 75%, protocol: 60 trains @ 50 pulses/train @ 10pps and Inter Train Interval 10 sec. >10.000 pulses